Lincoln Electric IM986 manual E-14, Possible, Troubleshooting, Problems, Recommended, Symptoms

Models: IM986

1 57
Download 57 pages 27.18 Kb
Page 51
Image 51
E-14

 

E-14

 

 

 

 

TROUBLESHOOTING

 

E-14

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

 

 

 

POSSIBLE

 

RECOMMENDED

 

 

(SYMPTOMS)

 

 

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

DeviceNet – PLC Controlled System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Limit Errors

 

 

4. Verify all welding setpoint values

 

 

 

Bad Welding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are within limits.

 

 

 

 

 

 

 

 

 

 

 

 

5. Gas

 

 

 

5. Verify Gas remains on until after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the weld is complete.

 

 

 

 

 

 

 

 

 

 

 

 

6. Welding set points

 

 

 

6. Verify welding set points for work

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point, trim, and wave values.

 

 

 

 

 

 

 

 

 

 

 

 

7. Wire Drive / Gear selection

 

 

 

7. Verify proper wire drive and gear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ratio has been selected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE

 

RECOMMENDED

 

(SYMPTOMS)

 

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

ETHERNET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cannot Connect.

1. Physical connection.

 

 

 

 

 

 

 

 

1. Verify that the correct patch cable or

 

 

 

 

 

 

 

 

 

 

 

 

 

cross over cable is being used (refer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to local IT department for assis-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tance).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• For direct connection to the Fanuc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R30iA Controller, use only the cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

provided with the K2677-1 Integration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Verify the cables are fully inserted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into the bulk head connector.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• LED 8 located under the PC board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ethernet connector will be lit when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the machine is connected to another

 

 

 

 

 

 

 

 

 

 

 

2. IP address information.

 

 

network device.

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Use Weld Manager (included on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER WAVE® Utilities and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service Navigator CDʼs or available

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at www.powerwavesoftware.com) to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

verify the correct IP address infor-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mation has been entered.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The IP address configuration MUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be set to dynamic when connected to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Fanuc R30iA Controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Verify no duplicate the IP addresses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

exist on the network.

 

 

 

 

 

 

 

 

 

 

 

3. Ethernet Speed.

 

 

3. Verify that the network device con-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

nected to the POWER WAVE® is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

either a 10-baseT device or a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100-baseT device.

 

 

 

 

Connection Drops while welding.

 

 

 

 

1. Cable Location.

 

 

1. Verify Network cable is not located

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

next to current carrying conductors.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This would include input power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cables and welding output cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSSIBLEManual background CAUTION