E-6

 

 

 

TROUBLESHOOTING

 

 

 

E-6

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

TROUBLESHOOTING GUIDE

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

 

detailed in the beginning of this manual.

 

PROBLEMS

 

POSSIBLE

 

RECOMMENDED

 

 

 

 

(SYMPTOMS)

 

CAUSE

 

COURSE OF ACTION

 

 

 

 

 

 

 

BASIC MACHINE PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine wonʼt weld, canʼt get any

 

 

1. Input voltage is too low or too

 

 

1. Make certain that input voltage is

 

 

output.

 

 

high.

 

 

correct, according to the Rating

 

 

 

(CR1 will not pull in.)

 

 

 

 

 

Plate located on the rear of the

 

 

 

This problem will normally be

 

 

 

 

 

machine.

 

 

 

 

 

 

 

2. Thermal Error.

 

 

2. See

“Thermal

LED

is

 

 

 

accompanied by an error code.

 

 

 

 

 

 

 

Error codes are displayed as a

 

 

 

 

 

ON” section.

 

 

 

 

 

series of red and green flashes by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Primary current limit has been

 

 

3. Possible short in output circuit.

 

 

 

the status light(s). See “Status

 

 

 

 

 

 

 

Light” section of this document for

 

 

exceeded. (the main contactor

 

 

Turn machine off. Remove all

 

 

 

additional information.

 

 

drops out when output is initiat-

 

 

loads from the output of the

 

 

 

 

 

 

 

ed – see error 31).

 

 

machine. Turn back on, and acti-

 

 

 

 

 

 

 

 

 

 

vate output. If condition persists,

 

 

 

 

 

 

 

 

 

 

turn power off, and contact an

 

 

 

 

 

 

 

 

 

 

authorized Lincoln Electric Field

 

 

 

 

 

 

 

 

 

 

Service facility.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Inverter Fault - switch pc board,

 

 

4. Contact your local authorized

 

 

 

 

 

 

 

contactor problem, etc.

 

 

Lincoln Electric Field Service

 

 

 

 

 

 

 

 

 

 

facility for technical assistance.

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal LED is ON.

 

 

1. Improper fan operation.

 

 

1. Check for proper fan operation.

 

 

 

 

 

 

 

 

 

 

(Fans should run whenever out-

 

 

 

 

 

 

 

 

 

 

put power is on.)

Check for

 

 

 

 

 

 

 

 

 

 

material blocking

intake

or

 

 

 

 

 

 

 

 

 

 

exhaust louvers, or for excessive

 

 

 

 

 

 

 

 

 

 

dirt clogging cooling channels in

 

 

 

 

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Output Rectifier board or Choke

 

 

2. After

machine has cooled,

 

 

 

 

 

 

 

thermostat.

 

 

reduce load, duty cycle, or both.

 

 

 

 

 

 

 

 

 

 

Check for material blocking

 

 

 

 

 

 

 

 

 

 

intake or exhaust louvers and

 

 

 

 

 

 

 

 

 

 

heat sink fins.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. DC Bus PC board thermostat.

 

 

3. Check for excessive load on

 

 

 

 

 

 

 

 

 

 

40VDC supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. Open thermostat circuit.

 

 

4. Check for broken wires, open

 

 

 

 

 

 

 

 

 

 

connections or faulty ther-

 

 

 

 

 

 

 

 

 

 

mostats on the DC Bus and

 

 

 

 

 

 

 

 

 

 

Output Rectifier heat sinks, and

 

 

 

 

 

 

 

 

 

 

Choke assembly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE® i400

Page 43
Image 43
Lincoln Electric IM986 manual Problems, Recommended, Symptoms, Course Of Action, Troubleshooting Guide, Possible, Cause