Lincoln Electric IM986 manual A-17, Other Set-Up Issues, Installation

Models: IM986

1 57
Download 57 pages 27.18 Kb
Page 26
Image 26
A-17

A-17

INSTALLATION

A-17

Connections Between Power Source and Optional DeviceNet PLC Controller. Hard Automation applica- tions and some earlier model controllers may require DeviceNet connectivity to control the power source. DeviceNet can also be used to monitor welding data, and system status information. The optional K2780-1 DeviceNet Kit is available for this purpose. It includes a 5 pin DeviceNet sealed mini style receptacle that mounts on the recessed control panel of the Power Wave i400, above the output studs. The DeviceNet cable is keyed and polarized to prevent improper con- nection. For best results, route DeviceNet cables away from weld cables, wire drive control cables, or any other current carrying device that can create a fluctuating magnetic field. DeviceNet cables must be sourced locally by the customer. For additional guide- lines refer to the “DeviceNet Cable Planning and Installation Manual” (Allen Bradley publication DN- 6.7.2).

The DeviceNet MAC ID and baud rate of the POWER

WAVE® i400 can be configured with the Diagnostics

Utility (included on the POWER WAVE® Utilities and

Service Navigator CDʼs or available at

www.powerwavesoftware.com).

OTHER SET-UP ISSUES

Selecting a Wire Drive and Setting the Wire Drive Gear Ratio. The POWER WAVE® i400 can accom- modate a number of standard wire drives including the AutoDrive 4R90 (default) and PF-10R. The feeder control system must be configured for both the wire drive type and gear ratio (high or low speed range). This can be accomplished via the Fanuc Teach Pendant (V7.30p14 or later) or with the Weld Manager Utility (included on the Power Wave Utilities and Service Navigator CDʼs or available at www.powerwavesoftware.com).

Additional information is also available in the “How To” section at www.powerwavesoftware.com.

POWER WAVE® i400

Page 26
Image 26
Lincoln Electric IM986 manual A-17, Other Set-Up Issues, Installation, The DeviceNet MAC ID and baud rate of the POWER