035-19992-001 Rev. A (0404)

HOW YOUR GAS FURNACE WORKS

Your furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may never have given much thought to the way your furnace operates. In order to get the safest and most efficient oper- ation from your furnace, you should understand how your furnace does its job.

When you set your thermostat to provide more heat in your home, you are starting the heating cycle of the furnace. First, the inducer motor starts to purge the heat exchanger of any remaining gases. Next, the hot surface ignitor glows and after a warm-up period the gas valve opens and ignition occurs. A short time later, the blower starts and dis- tributes the warm air throughout the home. When the temperature set-

3.Remove burner access panel.

4.Move gas control switch to the “OFF” position.

5.Replace burner access panel.

Should overheating occur, or the gas valve fail to shut off, turn the external manual gas valve in the gas supply line to the furnace to the “off” position and let the furnace cool off before shutting off the electrical power supply. Refer to Figure 8.

ting on your thermostat is reached, the gas valve closes, the main burners are turned off, and the blower continues to run until the remain- ing warm air in the system is distributed. When the blower stops, the heating cycle has ended.

START-UP AND SHUTDOWN INSTRUCTIONS

Read the Instructions Below Before Trying to Start the Furnace

OUTLET

PRESSURE

PORT

INLET

WRENCH BOSS

INLET PRESSURE PORT

 

VENT PORT

 

OUTLET

OFF

 

ON

MAIN REGULATOR

ON/OFF SWITCH

ADJUSTMENT

 

(Shown in ON position)

 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, and/or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING; smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

C.Use only your hand to push the gas control switch to the “on” posi- tion. Never use tools. If the switch will not operate by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Imme- diately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control, which has been under water.

Operating Instructions:

1.STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off all electric power to the appliance.

4.Remove burner door.

5.Move gas control switch to the “OFF” position. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to next step.

7.Move gas control switch to the “ON” position. Do not force.

8.Replace burner door.

9.Turn on all electric power to the appliance.

10.Set thermostat to the desired setting. Burner will light, which may take 30-60 seconds.

11.After three (3) trials for ignition, if the appliance will not operate fol- low the instructions, “TO TURN OFF THE APPLIANCE” and call your service technician or gas supplier.

To Turn Off the Appliance:

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be per- formed.

FIGURE 7: Gas Valve - White Rodgers

EXTERNAL MANUAL

SHUTOFF VALVE

TO GAS

 

 

 

 

 

 

 

 

 

TO GAS

SUPPLY

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DRIP

 

GROUNDED JOINT UNION

 

MAY BE INSTALLED

LEG

 

INSIDE OR OUTSIDE UNIT.

FIGURE 8: Gas Piping

NOTE: The spring-loaded safety cut-off switch, mounted under the blower deck will automatically cut off the electrical power supply to the furnace when the blower panel is removed. As a safety precaution, all electrical power and the gas supply to the furnace should be turned off before servicing.

FURNACE USER MAINTENANCE

Before proceeding, be sure the area is well ventilated. Turn the thermostat OFF. If the blower is running, wait until it stops automatically. Turn OFF the gas and electrical power supplies to the furnace. Check all metal parts and surfaces to be sure they have cooled to room temperature before you begin.

Every time the filters are changed the following items should be visually inspected:

Check combustion air and vent pipe for blockage or leakage.

Check all components to be sure they are in good condition and that there are no obvious signs of deterioration.

Check the drain lines to make sure there are no cracks or leaks.

Check for dirt or lint on any surfaces or on components. Do not try to clean any of the surfaces or components. Cleaning of the fur- nace and its components must be done by a qualified service pro- fessional.

4

Unitary Products Group

Page 4
Image 4
York GF8 HOW Your GAS Furnace Works, START-UP and Shutdown Instructions, Operating Instructions, To Turn Off the Appliance