York H*RA018 THRU 060, H*RA036 THRU 090 warranty 036-21121-002Rev. A

Models: H*RA036 THRU 090 H*RA018 THRU 060

1 20
Download 20 pages 10.07 Kb
Page 4
Image 4

036-21121-002 Rev. A (0602)

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils

 

FURNACE**

COIL

 

 

 

COOLING

 

 

UNIT MODEL

CFM RANGE

W

MODEL

RATED

NET MBH

SEER + TXV

SEER + TXV1

EER

 

(MIN.-MAX.)

CFM

 

 

W/O TDR

 

 

TOTAL

SENS.

+ TDR*

 

 

 

 

 

 

14,17

G1FA024S14,17

650

18.0

13.3

10.00

-

9.20

 

 

14

G1FA030S14

650

19.0

14.1

10.50

-

9.80

 

 

-

G1HD024

655

18.5

13.7

10.50

-

10.00

 

575

17

G1NA024S17G

650

18.0

12.5

10.00

-

9.40

H1RA018S06

14,17

G1UA024S14,17

650

18.0

13.3

10.00

-

9.20

725

 

14

G1UA030S14

650

19.0

14.1

10.50

-

9.80

 

 

 

 

14,17

G2FD024S14,17

650

19.0

14.1

10.50

-

9.80

 

 

17

G2FD030S17

650

19.4

14.4

10.50

-

9.90

 

 

14

G2FD035S14

650

19.4

14.4

10.50

-

9.90

 

 

14,17

G1FA024S14,17

850

23.8

17.6

10.00

-

9.15

 

 

14

G1FA030S14

800

24.4

18.1

10.50

-

9.55

 

 

14

G1FA036S14

800

24.0

18.1

10.00

-

9.00

 

 

17,21

G1FA036S17,21

850

25.0

18.5

10.00

-

8.95

 

 

-

G1HD024

820

23.2

17.2

10.00

-

8.80

 

 

-

G1HD036

800

24.4

18.1

10.60

-

9.80

 

 

17

G1NA030S17H

800

23.6

17.5

10.00

-

9.00

 

700

21

G1NA030S21B

800

23.6

17.5

10.00

-

9.00

H1RA024S06

14,17

G1UA024S14,17

850

23.8

17.6

10.00

-

9.15

900

 

14

G1UA030S14

800

24.4

18.1

10.50

-

9.55

 

 

 

 

14

G1UA036S14

800

24.0

18.5

10.00

-

9.00

 

 

17,21

G1UA036S17,21

850

25.0

18.5

10.00

-

8.95

 

 

14,17

G2FD024S14,17

800

24.4

18.5

10.50

-

9.55

 

 

17

G2FD030S17

850

25.0

18.5

10.60

-

9.65

 

 

14

G2FD035S14

850

25.0

18.9

10.60

-

9.65

 

 

17

G2FD036S17

850

25.6

18.9

10.70

-

9.70

 

 

14

G1FA030S14

1000

28.0

20.7

10.00

-

9.30

 

 

14

G1FA036S14

1000

29.2

20.3

10.25

-

9.40

 

 

17,21

G1FA036S17,21

1000

29.0

21.5

10.45

-

9.45

 

 

-

G1HD036

1000

29.6

21.9

10.00

-

9.55

 

875

17

G1NA030S17K

1000

29.0

20.4

10.00

-

9.30

H2RA030S06

21

G1NA030S21M

1050

29.0

20.4

10.00

-

9.20

1125

 

 

 

 

 

 

 

 

14

G1UA036S14

1000

29.2

20.3

10.25

-

9.40

 

 

 

17,21

G1UA036S17,21

1000

29.0

21.5

10.45

-

9.45

 

 

17

G2FD030S17

1000

29.0

21.5

10.30

-

9.45

 

 

14

G2FD035S14

1000

29.0

21.5

10.30

-

9.45

 

 

21

G2FD036S21

1000

30.0

22.2

10.50

-

9.65

 

 

14

G1FA036S14

1200

33.6

24.9

10.00

-

9.10

 

 

17,21

G1FA036S17,21

1200

33.6

24.9

10.00

-

9.10

 

 

17

G1FA048S17

1200

35.0

25.9

10.30

-

9.40

 

 

21,24

G1FA048S21,24

1200

36.0

26.6

10.40

-

9.40

 

 

-

G1HD036

1200

34.4

25.5

10.00

-

8.90

 

 

-

G1HD048

1165

34.8

25.8

10.00

-

8.95

 

 

17

G1NA036S17J

1200

34.4

25.5

10.00

-

9.20

 

1050

21

G1NA036S21C

1200

34.4

25.5

10.00

-

9.30

H2RA036S06

14

G1UA036S14

1200

33.6

24.9

10.00

-

9.10

1350

 

 

 

 

 

 

 

 

17,21

G1UA036S17,21

1200

33.6

24.9

10.00

-

9.10

 

 

 

17

G1UA048S17

1200

35.0

25.9

10.30

-

9.40

 

 

21,24

G1UA048S21,24

1200

36.0

26.6

10.40

-

9.40

 

 

14

G2FD035S14

1200

33.4

24.7

10.00

-

9.10

 

 

17

G2FD036S17

1200

33.8

25.0

10.00

-

9.20

 

 

21

G2FD036S21

1200

33.8

25.0

10.00

-

9.20

 

 

21

G2FD042S21

1200

34.4

25.5

10.15

-

9.30

 

 

17

G2FD046S17

1200

34.4

25.5

10.15

-

9.30

For Notes See Page 5.

4

Unitary Products Group

Page 4
Image 4