York H*RE024 warranty Typical Installation, Typical Field Wiring, 036-21315-001Rev. A

Models: H*RE024

1 16
Download 16 pages 56.84 Kb
Page 7
Image 7
TYPICAL INSTALLATION

036-21315-001 Rev. A (0502)

TYPICAL INSTALLATION

 

MINIMUM 18” SERVICE ACCESS

THERMOSTAT

 

60” OVERHEAD CLEARANCE ON ONE SIDE

TO FURNACE OR

 

 

 

CLEARANCE

WEATHERPROOF

 

AIR HANDLER

 

 

 

 

TERMINAL BLOCK

 

DISCONNECT

 

 

 

 

 

SWITCH

 

NEC CLASS 1 WIRING

 

 

 

NEC CLASS 2 WIRING

10” CLEARANCE

 

 

 

COIL AREA

 

 

TO INDOOR COIL

 

 

 

NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF.

SEAL OPENING(S) WITH

PERMAGUM OR EQUIVALENT

CONTROL ACCESS PANEL

TYPICAL FIELD WIRING

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

POWER WIRING

208/230-1-60

POWER WIRING

24 VOLT CONTROL WIRING

 

CONTROL WIRING

MINIMUM 18 GA. WIRE

 

 

 

 

FACTORY WIRING

(NEC CLASS 2)

 

 

 

 

 

 

 

 

FURNACE OR AIR HANDLER TERMINAL BLOCK

CONTACTOR

TERMINALS

GND.

LUGCOIL

CONDENSING UNIT

C Y R G W

* TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

*

Y R G W

ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

Unitary Products Group

7

Page 7
Image 7
York H*RE024 warranty Typical Installation, Typical Field Wiring, 036-21315-001Rev. A, Unitary Products Group