Nomenclature

288429-YIM-A-0307

This product must be installed in strict compliance with the installation instructions and any applicable local, state and national codes including, but not limited to building, electrical, and mechanical codes.

Before performing service or maintenance operations on unit, turn off main power switch to unit. Electrical shock could cause personal injury. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer or service agency.

This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system. Gage sets, hoses, refrigerant containers and recovery systems must be designed to handle R-410A. If you are unsure, consult the equipment manufacturer. Failure to use R-410A compatible servicing equipment may result in property damage or injury.

Due to system pressure, moving parts, and electrical components, installation and servicing of air conditioning equipment can be hazardous. Only qualified, trained service personnel should install, repair, or service this equipment. Untrained personnel can perform basic maintenance functions of cleaning coils and filters and replacing filters.

Observe all precautions in the literature, labels, and tags accompanying the equipment whenever working on air conditioning equipment. Be sure to follow all other applicable safety precautions and codes including.

Nomenclature

Wear safety glasses and work gloves. Use quenching cloth and have a fire extinguisher available during brazing operations.

Inspection

As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier’s freight bill. A separate request for inspection by the carrier’s agent should be made in writing.

Reference

Additional information is available in the following reference forms:

Technical Guide - DEX024-048, DEY060, 294604

General Installation - DEX024-048, DEY060, 288429

Electric Heat Accessory - 035-16605-003-E-0705

Renewal Parts

Contact your local York® parts distribution center for authorized replacement parts.

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes including, but not limited to, building, electrical, and mechanical codes.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system.

D 1

EX

024 A 06

Product Category

D = Single Package Air Conditioner

(Air Cooled)

Product Generation

1 = New or Current Design

Product Identifier

EX = R-410A 15 SEER

EY = R-410A 14 SEER

Voltage Code

06 = 208/230-1-60

25 = 208/230-3-60

46 = 460-3-60

Factory Installed Electric Heat

A = No Electric Heat Installed

Nominal Cooling Capacity (MBH)

024 = 24,000 BTUH

042 = 42,000 BTUH

030 = 30,000 BTUH

048 = 48,000 BTUH

036 = 36,000 BTUH

060 = 60,000 BTUH