GZKDJRRJDGHZ2[JZFJR
|
|
|
|
| |
AFFINITY SERIES |
|
|
| ||
DEY060 |
|
|
| ||
|
|
|
|
| |
|
|
|
|
| |
|
|
|
| ||
|
|
|
| ||
|
| TABLE OF CONTENTS |
| ||
General | . . . . . . . . . . 1 |
| Compressors | . . . 11 | |
Installation | . . . . . . . . . . 3 |
| Phasing | . . . 12 | |
| Limitations | . . . . . . . . . . 3 | Airflow Performance | . . . 12 | |
| Location | . . . . . . . . . . 4 |
| Blower Speed Selection | . . . 17 |
| Rigging And Handling | . . . . . . . . . . 4 | Operation | . . . 18 | |
| Ductwork | . . . . . . . . . . 7 |
| Cooling Sequence Of Operations | . . . 18 |
| Roof Curb | . . . . . . . . . . 7 |
| Heating Sequence Of Operations | . . . 18 |
| Filters | . . . . . . . . . . 7 | Maintenance | . . . 20 | |
| Condensate Drain | . . . . . . . . . . 7 |
| Normal Maintenance | . . . 20 |
| Service Access | . . . . . . . . . . 8 | Troubleshooting | . . . 20 | |
| Thermostat | . . . . . . . . . . 8 |
| Typical Wiring Diagrams | . . . 21 |
| Power And Control Wiring | . . . . . . . . . . 8 |
|
|
|
|
| LIST OF TABLES |
| ||
1 | Unit Limitations | . . . . . . . . . . 3 | 12 | Electric Heat Multipliers | . . . 15 |
2 | Unit Accessory Weights | . . . . . . . . . . 5 | 13 | DEX024 Superheat Charging | . . . 16 |
3 | Unit Dimensions Front | . . . . . . . . . . 5 | 14 | DEX030 Superheat Charging | . . . 16 |
4 | Unit Clearances | . . . . . . . . . . 5 | 15 | DEX036 Superheat Charging | . . . 16 |
5 | Electrical Data | . . . . . . . . . . 9 | 16 | DEX042 Superheat Charging | . . . 16 |
6 | Physical Data | . . . . . . . . . 10 | 17 | DEX048 Superheat Charging | . . . 17 |
7 | Side Duct Application | . . . . . . . . . 12 | 18 | DEY060 Superheat Charging | . . . 17 |
8 | Bottom Duct Application | . . . . . . . . . 13 | 19 | Delay Profile | . . . 18 |
9 | Additional Static Resistance | . . . . . . . . . 14 | 20 | Thermostat Signals (Single Phase Units) | . . . 19 |
10 | Electric Heat Minimum Supply Air | . . . . . . . . . 15 | 21 | Thermostat Signals (Three Phase Units) | . . . 19 |
11 | Indoor Blower Specifications | . . . . . . . . . 15 |
|
|
|
|
| LIST OF FIGURES |
| ||
1 | Component Location | . . . . . . . . . . 3 | 8 | Typical Field Control Wiring Diagram 2 Stage | . . . . 9 |
2 | Unit 4 Point Load Weight | . . . . . . . . . . 4 | 9 | Thermostat | |
3 | Unit Dimensions | . . . . . . . . . . 5 | Typical Field Power Wiring Diagram | . . . . 9 | |
4 | Dimensions Front and Bottom | . . . . . . . . . . 6 | 10 | Control Board Speed Tap Location | . . . 18 |
5 | Dimensions Back and Bottom | . . . . . . . . . . 6 | 11 | . . . 24 | |
6 | Roof Curb | . . . . . . . . . . 7 |
|
|
|
7 | Typical Field Control Wiring Diagram Single Stage |
|
|
| |
| Thermostat | . . . . . . . . . . 8 |
|
|
|
General
YORK® Affinity Models DEX and DEY units are factory assembled cooling units designed for outdoor installation on a roof top or a slab.
The units are completely assembled on rigid, removable base rails. All piping, refrigerant charge, and electrical wiring is factory installed and tested. The units require only electric power and duct connections at the point of installation.
The electric heaters have
Safety Considerations
This is a safety alert symbol . When you see this symbol on labels or in manuals, be alert to the potential for personal injury.
Understand and pay particular attention the signal words
DANGER, WARNING or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if
not avoided may result in minor or moderate injury. It is also
used to alert against unsafe practices and hazards involving only property damage.
Improper installation may create a condition where the operation of the product could cause personal injury or property damage. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for assistance or for additional information, consult a qualified contractor, installer or service agency.