York YMA024 warranty Cooling Performance Data, Outdoor Unit Model No

Models: YMA024

1 24
Download 24 pages 57.12 Kb
Page 16
Image 16
Manual background

036-21570-002 Rev. D (0605)

COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

YMA06011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

G2FA060S24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

1600

 

 

 

 

1800

 

 

 

 

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

62

62

67

72

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

57.6

59.5

57.0

62.3

58.7

59.1

61.0

58.3

63.3

60.1

60.6

62.5

59.5

64.2

61.5

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

56.2

53.7

44.2

44.1

30.5

57.7

56.6

46.8

46.4

31.9

59.3

59.5

49.4

48.8

33.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.5

3.6

3.6

3.6

3.6

3.5

3.6

3.6

3.6

3.6

3.5

3.6

3.6

3.6

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

55.1

56.6

53.8

59.1

57.7

56.6

58.2

54.9

60.2

58.8

58.2

59.9

56.0

61.3

59.9

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

53.6

52.0

42.7

42.6

30.3

55.2

54.7

45.2

45.0

31.5

56.8

57.3

47.8

47.4

32.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.0

4.0

4.0

4.1

4.2

4.0

4.1

4.1

4.1

4.2

4.1

4.1

4.1

4.1

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

52.6

53.6

50.5

55.8

56.7

54.2

55.5

51.5

57.1

57.6

55.9

57.3

52.6

58.4

58.4

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

51.1

50.3

41.2

41.2

30.1

52.7

52.7

43.7

43.6

31.2

54.4

55.2

46.2

46.0

32.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.5

4.5

4.5

4.6

4.7

4.6

4.6

4.5

4.6

4.7

4.6

4.6

4.6

4.7

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

50.1

50.7

47.3

52.6

55.7

51.8

52.7

48.2

54.0

56.3

53.6

54.6

49.1

55.4

56.9

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

48.5

48.7

39.7

39.8

29.9

50.3

50.8

42.2

42.2

30.8

52.0

53.0

44.6

44.6

31.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

5.0

5.0

5.0

5.1

5.2

5.1

5.1

5.0

5.1

5.2

5.1

5.1

5.1

5.2

5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

47.3

47.7

44.2

48.9

51.2

48.8

49.4

45.0

50.1

51.7

50.3

51.2

45.8

51.3

52.1

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

45.8

45.8

38.3

38.3

28.3

38.9

47.7

40.4

40.7

29.4

48.7

49.5

42.6

43.0

30.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

5.7

5.7

5.7

5.8

5.9

5.7

5.7

5.7

5.8

5.9

5.8

5.8

5.7

5.8

5.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

44.5

44.8

41.1

45.4

46.8

45.8

46.3

41.9

46.3

47.1

47.1

47.8

42.7

47.2

47.5

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

43.1

43.1

36.9

36.8

26.8

27.8

44.6

38.8

39.2

27.9

45.6

46.1

40.6

41.5

29.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

6.3

6.3

6.3

6.4

6.5

6.4

6.4

6.3

6.4

6.6

6.4

6.4

6.3

6.4

6.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

41.8

41.9

38.1

41.8

42.4

42.9

43.2

38.8

42.5

42.6

44.0

44.5

39.5

43.2

42.8

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

40.4

40.3

35.6

35.4

25.2

16.8

41.5

37.1

37.7

26.5

42.4

42.7

38.6

40.0

27.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

7.0

7.0

6.9

7.0

7.2

7.0

7.0

7.0

7.0

7.2

7.0

7.0

7.0

7.1

7.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

F2FP060

 

0.98

0.96

1.01

 

 

 

 

 

F2FV060

 

1.00

0.97

0.98

 

 

 

 

 

N1VSD20

G2FD060(S,H)24(T)

0.99

0.96

0.98

 

 

 

 

 

N1VSD20

G2FD061H24

1.01

0.98

0.98

 

 

 

 

 

N1AHD20

G2FD060(S,H)24(T)

1.00

1.00

1.00

 

 

 

 

 

N1AHD20

G2FD061H24

1.01

1.00

1.00

 

 

 

 

 

 

G1FA060S21,24

1.00

1.00

1.00

 

 

 

 

 

 

G2FD060(S,H)24

1.00

1.00

1.00

 

 

 

 

 

 

G2FD061H24

1.01

1.00

1.00

 

 

 

 

 

 

G1NA060S24T

0.98

0.96

0.99

 

 

 

 

 

 

G1HD060

0.98

0.97

1.00

 

 

 

 

 

 

G1HA60S24

0.99

0.97

0.99

 

 

 

 

 

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P*DUC20V

G1FA060S21

0.99

0.98

0.98

 

 

 

 

 

P*DUC20V

G2FD060(S,H)24

0.99

0.98

0.98

 

 

 

 

 

P*DUC20V

G2FD061H24

1.00

0.99

0.98

 

 

 

 

 

P1XUC16V

G1FA060S21

0.99

0.95

0.98

 

 

 

 

 

P1XUC16V

G2FD060(S,H)24

0.99

0.95

0.98

 

 

 

 

 

P1XUC16V

G2FD061H24

0.99

0.95

0.98

 

 

 

 

 

P1XUC20V

G1FA060S21

0.99

0.95

0.98

 

 

 

 

 

P1XUC20V

G2FD060(S,H)24

0.99

0.95

0.98

 

 

 

 

 

P1XUC20V

G2FD061H24

1.00

0.97

0.98

 

 

 

 

 

P1XUD20V

G1FA060S24

0.99

0.95

0.98

 

 

 

 

 

P1XUD20V

G2FD060(S,H)24

0.99

0.95

0.98

 

 

 

 

 

P1XUD20V

G2FD061H24

1.00

0.96

0.97

 

 

 

 

 

P1XDC20V

G2FD060(S,H)24

0.99

0.94

0.98

 

 

 

 

 

P1XDC20V

G1HA60H24

0.98

0.93

0.96

 

 

 

 

 

P1XDD20V

G2FD060(S,H)24

0.99

0.94

0.98

 

 

 

 

 

P1XDD20V

G2FD061H24

1.00

0.96

0.98

 

 

 

 

 

P1XDD20V

G1HA60H24

0.98

0.93

0.96

 

 

 

 

 

16

Unitary Products Group

Page 16
Image 16