York YMA024 warranty Cooling Performance Data, Outdoor Unit Model No

Models: YMA024

1 24
Download 24 pages 57.12 Kb
Page 12
Image 12
Manual background

036-21570-002 Rev. D (0605)

COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

YMA03011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

G2FD030S17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

800

 

 

 

 

1000

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

62

62

67

72

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

29.1

32.6

32.6

35.6

35.2

31.4

33.1

35.3

35.0

34.4

33.7

33.7

38.0

34.4

33.7

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

29.2

26.8

22.6

22.4

17.0

31.5

28.7

26.4

21.8

17.4

33.8

30.6

30.2

21.2

17.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

2.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

27.6

30.4

30.2

33.5

34.6

29.7

31.3

32.3

33.3

34.2

31.9

32.2

34.4

33.2

33.7

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

27.7

25.8

21.8

21.7

17.0

29.8

28.0

25.1

22.2

17.7

32.0

30.2

28.3

22.7

18.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

26.0

28.2

27.8

31.4

34.0

28.1

29.5

29.3

31.7

33.9

30.1

30.7

30.7

31.9

33.8

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

26.1

24.8

21.0

21.0

16.9

28.2

27.3

23.7

22.6

18.0

30.2

29.8

26.5

24.2

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.4

2.4

2.4

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.5

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

24.5

26.0

25.4

29.3

33.4

26.4

27.7

26.2

30.0

33.7

28.3

29.3

27.1

30.7

33.9

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

24.6

23.8

20.1

20.3

16.9

26.5

26.6

22.4

23.0

18.3

28.4

29.5

24.7

25.7

19.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.6

2.6

2.6

2.7

2.7

2.6

2.6

2.6

2.7

2.8

2.7

2.7

2.7

2.7

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

23.0

24.1

23.4

26.8

30.5

24.6

25.5

24.4

27.4

30.8

26.3

27.0

25.4

28.0

31.0

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

23.0

22.7

19.1

19.5

15.9

24.6

24.9

21.5

22.0

17.3

26.3

27.1

23.9

24.5

18.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.8

2.8

2.8

2.9

2.9

2.8

2.8

2.8

2.9

3.0

2.9

2.9

2.8

2.9

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

21.5

22.3

21.4

24.4

27.7

22.9

23.5

22.6

24.8

27.9

24.3

24.7

23.8

25.3

28.2

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

21.6

21.6

18.1

18.7

14.9

22.9

23.2

20.6

21.0

16.3

24.4

24.8

23.1

23.4

17.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.0

3.0

3.0

3.0

3.1

3.0

3.0

3.0

3.1

3.2

3.1

3.1

3.0

3.1

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

20.0

20.4

19.5

22.0

24.8

21.2

21.4

20.9

22.3

25.1

22.3

22.5

22.2

22.6

25.4

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

20.1

20.5

17.2

17.9

13.9

21.1

21.5

19.8

20.1

15.3

22.4

22.6

22.3

22.3

16.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.2

3.2

3.1

3.2

3.3

3.2

3.2

3.2

3.3

3.4

3.3

3.3

3.2

3.3

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

F2RC/F2FC036

 

0.99

0.97

0.99

 

 

 

 

 

F2RP/F2FP/F3FP030

 

0.99

0.97

0.99

 

 

 

 

 

N1VSB12

G2FD030(S,H)17(T)

1.01

0.99

0.94

 

 

 

 

 

N1AHB08

G2FD030(S,H)17(T)

1.00

1.00

1.00

 

 

 

 

 

N1AHB12

G2FD030(S,H)17(T)

1.00

1.00

1.00

 

 

 

 

 

 

G1FA036S14

1.01

1.00

1.00

 

 

 

 

 

 

G1FA036S17,21

1.00

1.00

1.00

 

 

 

 

 

 

G2FD030(S,H)17(T)

1.00

1.00

1.00

 

 

 

 

 

 

G2FD035(S,H)14(T)

1.00

1.00

1.00

 

 

 

 

 

 

G1NA036S17J

1.01

1.00

1.00

 

 

 

 

 

 

G1NA036S21C

1.01

1.00

1.00

 

 

 

 

 

 

G1HD036

1.02

1.02

1.00

 

 

 

 

 

 

G1HA036H14

1.03

1.00

1.00

 

 

 

 

 

 

G1HA036H17

1.03

1.01

1.00

 

 

 

 

 

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

P*DUA12V

G1FA036S14

1.01

0.99

0.94

 

 

 

 

 

P*DUB16V

G1FA036S17

1.02

1.03

0.94

 

 

 

 

 

P*DUB16V

G2FD030(S,H)17(T)

1.02

1.03

0.94

 

 

 

 

 

P*DUC20V

G1FA036S21

1.01

1.01

0.93

 

 

 

 

 

P1XUB12V

G1FA036S17

1.01

1.02

0.95

 

 

 

 

 

P1XUB12V

G2FD030(S,H)17(T)

1.01

1.02

0.95

 

 

 

 

 

P1XUC16V

G1FA036S21

1.01

1.01

0.93

 

 

 

 

 

P1XUC20V

G1FA036S21

1.01

1.00

0.93

 

 

 

 

 

P1XDB12V

G2FD030(S,H)17(T)

1.01

1.01

0.95

 

 

 

 

 

P1XDB12V

G1HA036H17

1.01

1.02

0.95

 

 

 

 

 

12

Unitary Products Group

Page 12
Image 12
York YMA024 warranty Cooling Performance Data, Outdoor Unit Model No