ADAPTATION TO DIFFERENT

KINDS OF GAS

To adapt the appliance to a different kind of gas from the one the appliance has been set for, follow the instructions below in their order.

GAS CONNECTION (Fig. 15)

LPG : use the rubber pipe holder «C».

 

Natural gas : use the pipe fitting «A».

 

Always insert the gasket «B» (Fig. 15). Then proceed

 

with the gas connection, as indicated in the relevant

 

paragraphs.

Fig. 14

FO 2127

HOB BURNERS

NOZZLES REPLACEMENT

-Remove the pan supports.

-Extract the caps and the wall baffles of the burners.

-Using a socket spanner 7 unscrew and remove (fig. 16) the nozzles replacing them with the ones required for the kind of gas in use (see table).

Reassemble the parts following the same procedure backwards.

These burners do not need any primary air regulation.

HOB BURNERS

ADJUSTMENT OF MINIMUM LEVEL

To adjust the minimum level:

1)turn the knob to the position of minimum flame;

2)remove the knob (Fig. 17);

3a) in case of conversion from natural gas to LPG,

tightly screw the by-pass screw of the cocks;

3b) when converting from LPG to natural gas unscrew about one-fourth turn by-pass screw, until a regular small flame is reached.

Reassemble the parts following the same procedure backards.

Check that, turning quickly the knob from the maximum position to the minimum one, the flame does not go out.

Fig. 15

Fig. 16

FO 0392

 

Normal power

Reduced power

NATURAL GAS

 

LPG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mark

m3/h

Mark

g/h

 

BURNER

 

 

1/100

 

 

1/100

 

 

 

kW

kW

G20

G25

G 30

 

G 31

 

 

 

 

 

 

 

20

25

 

 

 

 

 

 

mbar

mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

1

0,33

70

0,095

0,111

50

72,5

 

71,5

 

 

 

 

 

 

 

 

 

 

Semi-rapid

2

0,45

96

0,190

0,221

71

145

 

143

 

 

 

 

 

 

 

 

 

 

 

Natural gas:

 

 

 

 

 

 

 

 

Rapid

3

 

 

 

 

 

 

 

 

 

LPG : 2,8

0,65

119

0,286

0,332

86

203

 

200

 

 

 

 

 

 

 

 

 

 

70

Page 16