Installation

Positioning

This appliance can be installed in a dry, well ventilated
indoor (garage or cellar), but for optimum performance
install the appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on the
rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N+16°C to + 32°C
ST +16°C to + 38°C
T+16°C to + 43°C

Ventilation requirements

1. Put the freezer in horizontal position on a firm surface.
The cabinet must be on all four feet.
2. Make sure that the clearance between the appliance
and rear wall is 5 cm.
3. Make sure that the clearance between the appliance
and the sides is 5 cm.
The airflow behind the appliance must be sufficient.

Electrical Connection

Caution! Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
Warning! This appliance must be earthed.
The manufacturer declines any liability should these
safety measures not be observed.
1 2
3
4
5
Important! The wires in the mains lead are coloured in
accordance with the following code:
1
Green and Yellow: Earth
3
Brown: Live
5
Blue: Neutral
As the colours of the wires in the mains lead of this ap-
pliance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:
1. Connect the wire coloured green and yellow to the
terminal marked either with the letter “E“ or by the
earth symbol or coloured green and yellow.
2. Connect the wire coloured blue to the terminal either
marked with the letter “N“ or coloured black.
3. Connect the wire coloured brown to the terminal ei-
ther marked with the “L“ or coloured red.
4. Check that no cut, or stray strands of wire is present
and the cord clamp
4
is secure over the outer
sheath.
5. Make sure the electricity supply voltage is the same
as that indicated on the appliance rating plate.
6. Switch on the appliance.
The appliance is supplied with a 13 amp plug fitted
2
.
In the event of having to change the fuse in the plug sup-
plied, a 13 amp ASTA approved (BS 1362) fuse must be
used.
6