Instructions for the Installer
Engineers technical data
Overall dimensions
Width: | 580 mm. |
Depth: | 510 mm. |
Cut out dimensions
Width: | 560 mm. |
Depth: | 480 mm. |
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Rear Left Burner | |
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Left Burner | (auxiliary) |
Heat Input | 1.0 kW (3412 BTU/HR) |
Rear Right Burner | |
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Right Burner: | |
Heat Input | 4.0 kW (13652 BTU/HR) |
TYPE OF GAS | Characteristics | BURNER |
| AUXILIARY | |||||||
|
| (triple | crown) | (medium) | (small) | ||||||
|
|
|
|
|
|
|
| ||||
POSITION |
| MAX | MIN | MAX | MIN | MAX | MIN | ||||
|
|
|
|
|
|
|
| ||||
NATURAL GAS |
| VALUE = 37.78 MJ/m3 | Ws - 50.7 MJ/ m3 | NOMINALTHERMAL |
|
|
|
|
|
| |
20 mbar | POWER | kW | 4.0 | 1.2 | 2.0 | 0.45 | 1.0 | 0.33 | |||
NOMINAL FLOW |
|
|
|
|
|
|
| ||||
RATE | m3/h | 0.381 | 0.114 | 0.190 | 0.043 | 0.095 | 0.031 | ||||
NOZZLEREFERENCE | 146 | Adjust. | 96 | Adjust. | 70 | Adjust. | |||||
1/100 mm |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |
| VALUE = 49.92 MJ/Kg | NOMINALTHERMAL |
|
|
|
|
|
| |||
LPG GAS | POWER | kW | 4.0 | 1.2 | 2.0 | 0.45 | 1.0 | 0.33 | |||
NOMINAL FLOW |
|
|
|
|
|
|
| ||||
RATE | g/h | 288 | 86 | 144 | 32 | 72 | 24 | ||||
NOZZLEREFERENCE | 98 | 56 | 71 | 32 | 50 | 28 | |||||
1/100 mm |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
Burner | Dia. Tap |
| 1/100 mm |
|
|
Auxiliary | 28 |
32 |
Aeration adjustment none
APPLIANCE CLASS: | 3 |
APPLIANCE CATEGORY: | II2H3+ |
APPLIANCE GAS SUPPLY:Natural gas G20 / 20mbar
8