Zanussi ZGF 692 CT manual Fault Finding, Preliminary Electrical Systems Check, No Yes, Start

Models: ZGF 692 CT ZGF 692 C

1 32
Download 32 pages 6.29 Kb
Page 23
Image 23
Fault Finding

Fault Finding

Preliminary Electrical Systems Check

START

Isolate appliance and carry out:

A:Earth Continuity check.

NO YES

Carry out:

C:Polarity check.

Brown Blue

Blue

Brown Green

Yellow

Carry out:

D:Resistance to Earth check.

Has inlet fuse blown?

NO

Inlet wiring

YES

Electricity supply

 

 

should now be

 

 

 

satisfactory.

 

 

 

 

 

 

PLUG (with cover removed)

S O C K E T

(face view)

faulty. Rectify any fault.

Earth Wire Green/Yellow

Neutral Wire Blue

(

)

 

FUSE

E(Preliminary Electrical Systems Check)

N L

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

23