Zanussi ZGF 982 Installation, Gas Connection, Cut Out Size, Rectangular cut-out size for hob

Models: ZGF 982

1 17
Download 17 pages 8.94 Kb
Page 11
Image 11
Installation

Installation

IMPORTANT

This hob must be installed by qualified personnel to the relevant British Standards.

Any gas installation must be carried out by a registered CORGI installer.

The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored.

On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.

Gas Connection

Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel or copper.

The connection should be suitable for connecting to RC 1/2 (1/2 BSP male thread).

When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation.

Ensure that the main connection pipe does not exert any strain on the hob.

It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe.

Failure to ensure the correct assembly will cause leakage of gas.

Cut Out Size

The dimensions of the cut-out are given in the diagram.

FO 0814

FO 0264

A)End of shaft with nut

B)Washer

C)Elbow

Rectangular cut-out size for hob

 

 

min

.

 

 

55

 

 

 

 

 

 

480

 

 

30

 

 

 

 

830

 

Dimensions are given in mm.

150 min

FO 2349

12

Page 11
Image 11
Zanussi ZGF 982 Installation, Gas Connection, Cut Out Size, Rectangular cut-out size for hob, Dimensions are given in mm