6. Adaptation to different types of gas

6. Adaptation to different types of gas

INJECTORS REPLACEMENT

Remove the pan supports.

Remove the burner's caps and crowns.

With a socket spanner 7 unscrew and remove the injectors (Fig. 7), and replace them with the ones required for the type of gas in use (see table 2).

Reassemble the parts, following the same procedu- re backwards.

Replace the rating label (placed near the gas supply pipe) with the relevant one for the new type of gas supply. You can find this label in the package of the injectors supplied with the appliance.

Should the feeding gas pressure be different or variable compared with the required pressure, an appropriate pressure adjuster must be fitted on the gas supply pipe, in compliance with the rules in force.

ADJUSTMENT OF MINIMUM LEVEL

To adjust the minimum level of the burners, proceed as follows:

Light the burner.

Turn the knob on the minimum position.

Remove the knob.

With a thin screwdriver, adjust the by-pass screw (see Fig. 8). If changing from natural gas to LPG, completely tighten clockwise the screw, until a small regular flame is obtained.

Finally check the flame does not go out when quickly

turning the knob from the maximum position to the minimum position.

This procedure can easily be carried out, anyhow the hob has been positioned or built in the working top.

Table 2 : injectors - (*) suitable for G25 too.

Fig. 7

FO 0392

 

 

Fig. 8

FO 2031

 

Table 1 : By-pass diameters

Burner

Ø By-pass

 

in 1/100

 

of mm.

 

 

Double Crown

56

Auxiliary

28

Semi-rapid

32

Rapid

40

 

 

BURNER

NORMAL

REDUCED

 

 

NORMAL

 

 

 

 

POWER

POWER

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

kW

NATURAL GAS

 

LPG

 

 

 

 

G20 - 20 mbar

28-30/37 mbar

 

 

 

 

 

 

 

 

 

 

 

 

inj. 1/100

m3/h

inj. 1/100

g/h - G30

g/h - G31

 

 

 

 

 

 

 

 

 

Auxiliary (small)

1

0,33

70(*)

0,095

50

72

 

71

 

 

 

 

 

 

 

 

 

Semi-rapid (medium)

2

0,45

96(*)

0,190

71

145

 

143

 

 

 

 

 

 

 

 

 

 

Natural gas :

 

 

 

 

 

 

 

Rapid (big)

3

0,65

119(*)

0,286

86

203

 

200

 

LPG : 2,8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double Crown Burner

3,5

1,2

136(*)

0,333

93

254

 

250

 

 

 

 

 

 

 

 

 

38