Problem
The flame is blow out immediately af- ter ignition
The gas ring burns unevenly
Possible cause
•Thermocouple is not heated suffi- cient
•Burner crown is blocked with food residues
Remedy
•After lightning the flame, keep the knob pushed for approximately 5 seconds.
•Make sure that the injector is not blocked and the burner crown is clear of food particles.
If there is a fault, first try to find a solution to the problem yourself. If you cannot find a solution to the problem yourself, speak your dealer or the local Service Force Centre.
If you operated the appliance incorrectly, or the in- stallation was not carried out by a registered engi-
neer, the visit from the customer service technician or dealer may not take place free of charge, even during the warranty period.
Labels supplied with the accessories bag
Stick the adhesive labels as indicated below:
| 1 |
|
| 2 |
|
|
| 3 |
| ||||||
MOD. |
|
|
| MOD. |
|
|
|
| MOD. |
|
|
| TYPE | ||
|
|
|
| ||||||||||||
PROD.NO. | PROD.NO. | 0049 | PROD.NO. |
|
|
| |||||||||
SER.NO. |
|
|
| IP20 | |||||||||||
SER.NO | SER.NO |
|
|
| |||||||||||
03 IT |
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
DATA | DATA | MADE IN ITALY |
|
|
|
|
|
MODEL
MODEL
1Stick it on Guarantee Card and send this part
2Stick it on Guarantee Card and keep this part
3Stick it on instruction booklet
These data are necessary to help you quickly and correct- ly. These data are available on the identification plate from the injectors kit.
• Model description .................
•Product number (PNC)
•Serial Number (S.N.) ..................................
Use the original spare parts only. They are available at Service Force Centre and approved spare parts shops.
Technical data
Hob dimensions
Width:
580 mm
Length:
500 mm
10