Venting

Venting

The hood is more effective when used in the extraction setting (ducted to the outside).

Venting kits maybe purchased through your retailer or DIY store, and must be ducted to an outside vent of 100mm (4”) minimum.

The ducting used must be manufactured from fire retardant material which should conform to the relevant British Standard or DIN4102-B1.

When the hood is ducted externally the charcoal filter must be removed and the slider control must be in the ducting position.

 To Fit the Ducting To Fit the Ducting

1.Fit the ducting spigot and blanking plate, by aligning the interlocking lugs on the fittings, with the recesses in the aperture.

2.Insert and turn anti-clockwise to lock spigot and blanking plate into position.

3.Remove the charcoal filter and ensure the slider control is in the ducting position.

 To Remove the Charcoal Filter To Remove the Charcoal Filter

1.Remove the metal inlet grille.

2.Carefully twist the plastic disc anticlockwise, while holding the charcoal filter secrurely.

3.Clean the metal inlet grille and motor support before replacing the charcoal filter.

Recirculation

The charcoal filter must be fitted for recirculation and the slider control must be in the recirculation position.