Please examine the appliance for any damage. If the appliance is damaged contact your retailer before the appliance is connected.
Please keep packaging away from children and dispose of with due regard for the environment.
Important Safety Requirements
•The hob must be installed by a qualified electrician / competent person.
•Damaged hobs with cracks or breakages in the ceramic glass must not be connected to the electrical supply.
•This hob must be installed in accordance with the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes of Practice: B.S.6172 / B.S.5440 Part 2 and B.S.6891 Current Editions.
Disposal
All packaging parts are recyclable, wooden strips are
Installation into the kitchen worktop
Protection against accidental contact according to the regulations set by VDE or other local authorities and EN60335 must be ensured by the correct installation of the appliance. The same refers to the back of the appliance which, even in the case of
| Measurement of: |
| |
|
|
| |
Worktop Opening | Appliance: |
| |
Width: | 560mm | Width: | 572mm |
Depth: | 490mm | Depth: | 502mm |
Corner Radius:5mm | Height: | 49mm | |
|
|
| |
Voltage: |
| AC 230 V 50 Hz/60Hz | |
Total Connection Load: 5.8 kW |
|
12