Electrical Connection

Electrical Connection

Theovenisdesignedtobeconnectedto230V(50 Hz) electricitysupply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L -

Live terminal

Letter N-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earthterminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Letter L - THIS OVEN MUST BE EARTHED

Thecableusedtoconnecttheoventotheelectrical supply must comply to the specifications given below.

It is necessary that you install a double pole switch betweentheovenandtheelectricitysupply(mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

the yellow and green earth cable should be 2-3 cm longer than the other cables.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load and that the power supply is properly earthed.

The manufacturer declines any responsibility should these safety measures not be carried out.

Connection
Min.size
Cable/flex
Fuse

via

Cable/flex

type

 

13 A socket2.5 mm23 core

13 A min.

outlet

 

butyl

 

 

 

insulated

 

13 A spur box

 

 

 

 

 

Oven

2.5 mm2

PVC/PVC

15 A min.

Control

 

twin and
Circuit

 

earth20Amax.

 

 

For Europe use only

Min. size Cable/

Cable / flex type

Fuse

flex

 

 

 

 

 

 

2.5 mm2

H07 RN-F, H05 RN-F,

15 A

 

H05

RR-F, H05 VV-F,

 

 

H05

V2V2-F (T90),

 

 

H05

BB-F

 

 

 

 

 

23

Page 23
Image 23