Zanussi ZVH 66 F manual Installation Instructions, Safety instructions, Sticking on the seal

Models: ZVH 66 F

1 28
Download 28 pages 3 Kb
Page 20
Image 20
Installation Instructions

Installation Instructions

1Safety instructions

Warning! This must be read!

The laws, ordinances, directives and standards in force in the country of use are to be followed (safety regulations, proper recycling in accord- ance with the regulations, etc.)

Installation may only be carried out by a quali- fied electrician.

The minimum distances to other appliances and units are to be observed.

Anti-shock protection must be provided by the installation, for example drawers may only be installed with a protective floor directly under- neath the appliance.

The cut surfaces of the worktop are to be pro- tected against moisture using a suitable seal- ant.

The sealant seals the appliance to the work top with no gap.

Avoid installing the appliance next to doors and under windows. Otherwise hot cookware may be knocked off the rings when doors and win- dows are opened.

zRisk of injury from electrical cur- rent.

The electrical mains terminal is live.

Make electrical mains terminal free of volt- age.

Follow connection schematic.

Observe electrical safety rules.

Ensure anti-shock protection by installing correctly.

The appliance must be connected to the electrical supply by a qualified electrician.

zRisk of injury from electrical cur- rent.

Loose and inappropriate plug and socket connections can make the terminal overheat.

Have the clamping connections correctly in- stalled by a qualified electrician.

Use strain relief clamp on cable.

In the event of single-phase or two-phase connection, the appropriate mains cable of type H05BB-F Tmax 90°C(or higher) or an equivalent type must be used.

If this appliance’s mains cable is damaged, it must be replaced by a special cable (type H05BB-F Tmax 90°C; or higher) or an equiv- alent type. The latter is available from the Customer Care Department.

A device must be provided in the electrical in- stallation which allows the appliance to be dis- connected from the mains at all poles with a contact opening width of at least 3 mm. Suitable isolation devices include line protect- ing cut-outs, fuses (screw type fuses are to be removed from the holder), earth leakage trips and contactors.

Sticking on the seal

Clean the worktop around the cut-out area.

Stick the single-sided adhesive sealing tape provided on the underside of the hob around the outside edge ensuring that it is not stretched. The two ends of the tape should join in the middle of one side. After trimming the tape (allow it to overlap by 2-3 mm), press the two ends together.

20

Page 20
Image 20
Zanussi ZVH 66 F manual Installation Instructions, Safety instructions, Sticking on the seal