Technical Data
Gas Burners Rating
Auxiliary Burner |
| 1 kW |
Semirapid Burner |
| 2 kW |
Appliance Class |
| 3 |
Category |
| II 2H3B/P |
Setting |
|
|
LPG G30/G31 30/37 mbar |
| |
Gas connection |
| G 1/2" |
Electric hotplates |
| |
Small hotplate | Ø 145 mm. | 1000 W |
Large hotplate | Ø 180 mm. | 2000 W |
Electric Supply |
| |
230 V ~ 50 Hz |
|
|
Hob recess dimensions |
| |
Length |
| 550 mm. |
Width |
| 470 mm. |
Instruction for the Installer
The following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force.
The side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top.
Avoid installing the appliance in the proximity of inflammable materials (e.g. curtains, tea towels etc.).
The appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensureallthenecessaryprecautionsarefollowed.
THE MANUFACTURER WILL NOT ACCEPT
LIABILITY, SHOULD ANY OF THE OTHER SAFETY
INSTRUCTIONS INCORPORATED IN THIS BOOK
OR THE REGULATION IN FORCE BE IGNORED.
7