Contents
For the User |
| For the Installer |
|
Important Safety Information | 2 | Technical Data | 7 |
Instruction for the User | 3 | Instruction for the Installer | 7 |
Cleaning and Maintenance | 6 | Gas connection | 8 |
European Guarantee | 13 | Electrical Connection | 9 |
|
| Adaptation to different types of gas | 10 |
|
| Building In | 11 |
This appliance complies with the following | Possibilities for insertion | 12 | |
|
| ||
E.E.C. Directives: |
| MANUFACTURER: |
|
- 2006/95 (Low Voltage Directive); |
|
| |
- 2004/108 (Electromagnetical Compatibility Directive); | ELECTROLUX ITALIA S.p.A. |
| |
- 90/396 (Gas Appliances Directive ) |
| C.so Lino Zanussi 30 |
|
and subsequent modifications. |
| 33080 Porcia (PN) - ITALIA |
|
Instruction for the User
Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory.
Hob burners control knobs
The hob burners control knobs are situated on the hob right hand side. The symbols on the knobs mean that:
there is no gas supply
there is maximum gas supply there is minimum gas supply
Lighting the burners
For easier lighting, proceed before putting a pan on the pan support.
To light a burner, push in the relevant knob and turn it counterclockwise to "maximum position". After lighting the flame, keep the knob pushed down for about 5 seconds. This will allow the "thermocouple" (Fig. 1, lett. D) to be heated and the safety device to be switched off, otherwise the gas supply would be interrupted.
Then, check the flame is regular and adjust it as required.
If you cannot light the flame even after several attempts, check the "cap" (Fig. 1, lett. A) and the "crown" (Fig. 1, lett. B) are in the correct position. To put the flame out, turn the knob to the symbol .
•Always turn the flame down or put it out before taking the pans off the burner.
Manual
Fig. 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
FO 0204 |
A - Burner cap
B - Burner crown
C - Ignition candle
D - Thermocouple
Do not keep the control knob pressed for more than 15 seconds.
If the burner does not light even after 15 seconds, release the control knob, turn it the “off” position and wait for at
least one minute before trying to light the burner again.
3