Parallel Interface

The figure below displays the cable wiring required to use the printer's Centronics parallel interface.

HOST

STROBE~

DATA 0

DATA 1

DATA 2

DATA 3

DATA 4

DATA 5

DATA 6

DATA 7

ACK~

BUSY

PAPER ERR.

SELECT

AUTOFD~

ERROR~

N/A

N/A

N/A

SIG. GND SIG. GND SIG. GND SIG. GND SIG. GND SIG. GND SIG. GND

DB-25

Pin No.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

Centronics

Pin No. PRINTER

1

 

 

 

STROBE~

2

 

 

 

DATA 0

 

 

3

 

 

 

DATA 1

 

 

4

 

 

 

DATA 2

 

 

5

 

 

 

DATA 3

 

 

6

 

 

 

DATA 4

 

 

7

 

 

 

DATA 5

 

 

8

 

 

 

DATA 6

 

 

9

 

 

 

DATA 7

 

 

10

 

 

 

ACK~

 

 

 

11

 

 

 

BUSY

 

 

 

12

 

 

 

PAPER ERR.

 

 

 

13

 

 

 

SELECT

 

 

 

14

 

 

 

AUTOFD~

 

 

 

15n/c

16SIG. GND

17CHAS GND

18 +5V

19SIG. GND

20SIG. GND

21SIG. GND

22SIG. GND

23SIG. GND

24SIG. GND

25SIG. GND

26SIG. GND

27SIG. GND

28SIG. GND

29SIG. GND

30SIG. GND

31n/c

32 ERROR~

33SIG. GND

34n/c

35n/c

36 SELECTIN~

Male DB-25 to Male Centronics (Cable)

42

980481-001A

Page 50
Image 50
Zebra Technologies LP 2824 manual Parallel Interface, Host