9 - 37
–+
ELEC
SIGNAL SYSTEM
EB806024
2.If the neutral indicator light fails to come on:
CONTINUITY
1.Bulb and bulb socket
●Check the bulb and bulb socket for
continuity.
NO CONTINUITY
Replace the bulb and/or bulb socket.
CONTINUITY
2.Neutral switch
Refer to “CHECKING THE SWITCHES”.
NO CONTINUITY
Replace the neutral switch.
3.Voltage
●Connect the pocket tester (DC 20 V) to the
bulb socket coupler.
Tester (+) lead → Red/White terminal 1
Tester (–) lead → Sky blue terminal 2
MEETS
SPECIFICATION
●Turn the main switch to “ON”.
●Check the voltage (12 V).
This circuit is not faulty.
OUT OF SPECIFICATION
The wiring circuit from the main switch to the
bulb socket connector is faulty, repair it.