9 - 45
–+
ELEC
COOLING SYSTEM
C0NTINUITY
TURNS
4.Fan motor
●Disconnect the fan motor coupler.
●Connect the battery (12 V) as shown.
Battery (+) lead → Blue terminal 1
Battery (–) lead → Black terminal 2
●Check the operation of the fan motor.
*
DOES NOT TURN
Replace the fan motor.
MEETS
SPECIFICATION
5.Circuit breaker (fan motor)
●Remove the circuit breaker from the wire
harness.
●Connect the pocket tester (Ω × 1) to the
circuit breaker.
Circuit breaker resistance:
Zero Ω at 20 °C (68 °F)
*
OUT OF SPECIFICATION
Replace the circuit breaker.