COOLING SYSTEM

* C0NTINUITY

ELEC

+

6.Thermo switch (radiator)

Remove the thermo switch (radiator) from the radiator.

Connect the pocket tester (Ω ⋅ 10) to the thermo switch (radiator) 1.

Immerse the thermo switch (radiator) in coolant 2.

Check the thermo switch (radiator) for continuity.

While heating the coolant use a thermometer 3 to record the temperatures.

Test

Coolant temperature

 

Thermo switch

Continuity

step

(radiator)

 

 

 

 

 

 

1

Less than 86 ± 3 °C

NO

(186.8 ± 5.4 °F)

 

 

 

 

 

2

More than 86 ± 3 °C

YES

(186.8 ± 5.4 °F)

 

 

 

 

 

3

More than 80 ± 3 °C

YES

(176 ± 5.4 °F)

 

 

 

 

 

4

Less than 80 ± 3 °C

NO

(176 ± 5.4 °F)

 

 

 

 

 

Test steps 1 & 2: Heating phase

Test steps 3 & 4: Cooling phase

ÈThe thermo switch (radiator) circuit is open and the radiator fan is off.

ÉThe thermo switch (radiator) circuit is closed and the radiator fan is on.

WARNING

Handle the thermo switch (radiator) with special care.

Never subject it to a strong shock or allow it to be dropped. Should it be dropped, it must be replaced.

 

Thermo switch (radiator):

R

28 Nm (2.8 m • kg, 20 ft • lb)

T

 

 

 

 

.

Three bond sealock® #10

.

 

 

 

 

 

 

 

 

 

 

 

GOOD

 

 

 

 

 

 

 

 

CONDITION

 

 

 

 

 

 

 

 

*

É

 

 

 

È

 

 

 

 

 

 

 

 

 

 

80 ± 3 ˚C

86 ± 3 ˚C

(176 ± 5.4 ˚F)

(186.8 ± 5.4 ˚F)

BAD CONDITION

Replace the thermo switch (radiator).

9 - 46

Page 353
Image 353
Yamaha 5TE-F8197-10, LIT-11616-16-02 service manual Less than 86 ± 3 C 186.8 ± 5.4 F, 176 ± 5.4 F, Good