Zenith 216666666 Service Procedures, Tap Temperature Adjustment, Removing the case

Models: 216666666

1 8
Download 8 pages 28.62 Kb
Page 7
Image 7
Service Procedures

#

 

Service Procedures

 

 

 

This appliance may only be serviced by a suitably qualified technician.

 

 

Disconnect from power and turn water supply OFF before attempting any kind

 

 

of service work.

 

 

Removing the case

 

 

1. Remove temperature control knob by gripping it and pulling towards you.

 

 

2. Remove the single retaining screw located beneath the temperature control knob.

 

 

3. Remove the four case screws two at top, two at bottom.

 

 

4. The case can now be lifted off carefully.

 

 

Replacing the case

 

Knob removed to show screw

Reverse of the above procedure.

 

Replacing a thermostat

 

 

 

 

1. Remove the front cover.

 

 

2. Disconnect the two electrical terminals from the thermostat. These are

 

 

spade connectors and can be easily pulled off.

 

 

3. Remove the two screws attaching the thermostat to the plastic upright.

 

 

4. Pull the capillary out of the thermostat pocket located on the element

 

 

assembly.

 

 

5. Take the new thermostat (Z90421) and uncoil about half of the capillary tube.

 

 

6. Push the new capillary into the pocket ensuring that:

 

 

a) if it is an over sink model, the cutout bulb goes in first then the

 

 

thermostat bulb behind it.

 

 

b) if it is a under sink model, then the reverse is applicable.

 

Thermostat spade connectors

Attach the thermostat to the plastic upright.

 

 

 

 

Reconnect the two electrical terminals. It does not matter which way around

 

 

the connections occur.

 

 

Ensure the remaining capillary coil is out of the way of any live terminals.

 

 

Ensure the plastic upright is located securely in the position provided.

 

 

Refit the cover assembly.

#

Top Ring “X”

Mixer Cartridge “Y”

Tap Temperature Adjustment

Adjustment of a tap temperature limiter on Solo and Hero vented taps should be made only by a Zenith Service Provider or a qualified

technician.

1.Remove tap handle assembly to expose the mixer cartridge.

2.Lift and rotate the serrated top ring "X" from the mixer cartridge "Y".

Rotating the ring left or right will regulate the water temperature. Rotating the ring clockwise will increase the water temperature. Rotating the ring anticlockwise will decrease water temperature. The tap normally operates with the ring in the central position.

3.Reassemble the tap handle assembly to its original condition.

4.Test the temperature of the water outlet to check acceptability.

 

 

 

 

 

ZenithZenithudorTudor- Install- Installationtion & &OperatingOperatingInstructionsInstructions- 81333- 81333- May- July2003- 2004

Page 7

Page 7

 

 

 

 

 

Page 7
Image 7
Zenith 216666666 Service Procedures, Tap Temperature Adjustment, Removing the case, Replacing the case

FAQ

Can I service the water heater myself?

No, this appliance may only be serviced by a suitably qualified technician.

How can I adjust the tap temperature?

You can adjust the tap temperature by following the provided instructions for rotating the top ring on the mixer cartridge.

Is it necessary to disconnect the water heater from power before service work?

Yes, it is essential to disconnect from power and turn the water supply off before attempting any kind of service work.