CONVERTIBLE OPTIONS

13

INSTALLATION

CONVERTIBLE OPTIONS

Cyclone series: AK6000, 6036, 6042, 6048

Zephyr’s Cyclone series are equipped with the option of a 6“ vertical discharge, 3-1/4x10” vertical discharge, or 3- 1/4x10” rear discharge. Additional accessories are provided to convert to either of the above discharge methods.

Convertible Options

Vertical discharge

6“ round

Vertical discharge

3-1/4 x 10“

Horizontal rear discharge

3-1/4 x 10”

Convertible Accessories

6“ round duct cap

Round to rectangular transition adaptor

Rectangular to round transition adaptor (pre-

mounted)

Gasket (pre-mounted)

Rectangular rear cap (pre-mounted)

3-1/4 x 10“ starting collar

Back Splash

Cyclone models also come with a standard back splash. If desired, install back splash to rear of range hood with screws provided after all duct conversion steps below are completed.

3-1/4 x 10“ Vertical Discharge

1.Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place.

2.Place rectangular transition adaptor as shown over gasket and by first installing 4 screws on half round section.

3.Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws.