3-1/4 x 10“ Rear Discharge

INSTALLATION

14

3-1/4 x 10“ Rear Discharge

4.At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket.

6. Remove 2 arch blocks through top opening.

5.Remove top pre-mounted transition piece. Leave attached gasket in its original place.

7.Mount Starting Collar (provided) at rear discharge opening with gasket previously removed.

Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket.

Cap opening with 6“ cap provided OR, use option 2 if cabinet base is not recessed.