12. Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical shock.
Remove the Junction box cover and knockout and install the conduit connector (cULUS listed) in junction box cover.
Run 3 wires; black, white and green ,according to the National Electrical Code and local codes and ordi- nances, in 1/2" conduit from service panel to junction box.
Connect black wire from service panel to black or red in junction box, white to white and green to
Close junction box cover.
13.For Ductless (recirculating) installations
Install one charcoal filter (available as an extra kit).
14.Check all light bulbs to make sure they are secure in their sockets.
Turn power on in service panel. Check lights and blower operation.
15.Install filter.
If range hood does not operate:
•Check that the circuit breaker is not tripped or the house fuse blown.
•Disconnect power supply. Check that wiring is correct.
13