Installation

1.If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.

2.Remove the metal filter (see paragraph "Mainte- nance") top access the inside of the range hood.

3.Perform any necessary cutout on cabinet and wall as per "Dimensions and clearances" paragraph for range hood mounting and for vent system and conduit passage.

Use the supplied template to perform the cut out on cabinet.

Tape the template on the bottom of the cabinet, check that printed arrows match with the front edge of the cabinet (without considering the cabinet door).

Cut as indicated.

4.Install the vent system before the range hood. See „Venting methods“ and „Dimensions and clear- ance“ paragraphs.

Note - for Ductless - recirculating - installations: Purchase the Ductless recirculating kit Cabinet without ceiling:

Vent system is not required.

Cabinet with ceiling:

A 6" section of duct may be required to connect transition to deflector.

5.Install a conduit long enough to reach the junction

box.

Run wires through hole according the National Electrical Code or CSA Standards and local codes and ordinances.

There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the connection in the hood’s Junction box/es.

Use caulking to seal all openings on wall. Do Not turn on power until installation is completed.

6. Fit the transition on top of the hood.

7.Regulate the rear spacer to cover the clearance on the rear side once the hood has been installed (see also paragraph "Dimensions and clearances") and fix it with two screws (one per side).

Spacer Spacer fixing screw

A

see Dimensions and Clearances