Assembling the duct cover support bracket (3 parts):

The three parts should be fixed with 4 screws, the support extension is adjustable and should correspond to the internal width of the upper duct cover.

 

Duct

X

 

cover

 

 

support

Upper

 

bracket

 

 

Duct

 

=

cover

=

 

X

 

 

 

1.If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.

2.Determine and mark the centerline on the wall where the canopy hood will be installed.

3.Select a mounting height comfortable for the user and mark on wall behind cooktop.

4.Tape template, matching center-line and hood bottom as shown in Figure below.

5.Place the lower support bracket on the template making it coincide with the traced triangle, mark center of two fastener location and one lower fastener location then remove template.

centerline

fasteners

C

 

locations

lower

 

L

 

 

support

 

 

bracket

mounting height reference

6.Mark wall with horizontal line 1" above highest and 1" below lowest fastener location.

7.Find studs behind drywall by tapping wall or using a stud finder. Mark the center of the studs with a vertical line to the right and left of the marked fastener location.

8.Note: all fastener location must span the studs otherwise proceed as follows:

Cutout drywall along marked lines. Install each necessary between studs firmly flush with already existing stud front. Make sure all mounting screws will anchor to added studs. Replace drywall and refinish.

9.Determine and make all necessary cuts in the wall for the vent system. Install the vent system before the canopy hood. See „Venting methods“ and „Dimensions and clearance“ paragraphs.

Note - for Ductless - recirculating - installations: Vent system is not required.