■ Using MIDI to change effect parameters | Recalling Factory Default Memory Settings |
The 1204 allows the use of MIDI control change messages to change effect parameters. This includes all parameters except changing the effect type (as performed with the EFFECT selector or BANK switch) and adjusting the INPUT and OUTPUT level controls. Using control change messages to change effect parameters is called
To change effect parameters via MIDI, proceed as follows.
1.Connect the MIDI OUT jack of the external device to the MIDI IN jack of the 1204. Turn all devices off before making this connection.
2.When connections are established, turn on the devices and use the MODE key of the 1204 to set it to the memory mode.
3.Set up the 1204 so that the MIDI receive channels match the MIDI send channels of the external device.
4.Send control change messages from the external device to change effect parameters at the 1204.
Note: The relationship between MIDI control change messages and effect parameters of the 1204 is as shown below.
Effect parameter | MIDI control change number |
|
|
PATTERN select | 84 |
EDIT1 control | 85 |
EDIT2 control | 86 |
EQ LOW control | 87 |
EQ HIGH control | 88 |
MIX LEVEL control | 8 |
EFFECT ON, OFF | 80, 91 |
■ 22 ■
The 1204 is shipped from the factory with 100 recommended effect settings already stored in memory. When the user stores settings in memory, these factory defaults are overwritten, but they can be restored using the recall function. The recall mode is a special mode of the 1204 that is separate from the other two operation modes. It cannot be activated when the unit is already turned on. The unit must be turned off and then turned on by a special procedure, as described below.
In recall mode, all 100 settings can be restored together, and it is also possible to restore individual settings.
To use the recall mode, proceed as follows.
1.Turn the unit off.
2.Keep the STORE key depressed while turning the unit on with the POWER switch.
3.The indication A L "AL" flashes on the display.
4.When wishing to restore all 100 settings together, press the STORE key once more in this condition. The indication on the display flashes more rapidly. When the recall process is completed, the unit automatically switches to the memory mode.
5.When wishing to restore only a particular memory number, use the ▲ and ▼ keys to select the desired number in step 3.
6.When the desired memory number is displayed, press the STORE key. The indication on the display flashes more rapidly and the contents of that memory number are returned to the factory default.
7.Because the unit does not automatically switch to the memory mode when individual memory numbers are being restored, it is possible to restore several numbers in succession. When you wish to terminate the recall mode, press the CANCEL key. The 1204 then switches to the memory mode. Turning the unit off also terminates the recall mode.