ZyXEL Communications 3356P user manual Extended AT& Command Set

Models: 3356P

1 30
Download 30 pages 16.95 Kb
Page 21
Image 21

Command

Options

Function & Description

 

Z0

Reset and recall user profile 0. Either Z0 or

 

 

Z1 restores the same single profile.

*Manufacturer default

Extended AT& Command Set

Command

Options

Function & Description

&Cn

 

Data carrier detect option

 

&C0

State of carrier from remote modem is ignored. DCD circuit is always on

 

&C1 *

DCD turns on when the remote modem’s carrier signal is detected, and

 

 

off when the carrier signal is not detected.

&Dn

 

Data Terminal Ready (DTR) option.

 

&D0

DTR ignored

 

&D1

Go to command mode on on-to-off DTR transition

 

&D2 *

Hang up and go to command mode on on-to-off DTR transition. Auto-

 

 

answer is disabled if DTR is low

 

&D3

Hang up and reset from user profile 0 on the on-to-off DTR transition

&F

 

Recall factory default setting as active configuration

&Gn

 

V.22bis guard tone option

 

&G0 *

No guard tone

 

&G1

550 Hz guard tone

 

&G2

1800 Hz guard tone

&Kn

 

Set local flow control

 

&K0

Disable flow control

 

&K3 *

Enable bi-directional hardware flow control (CTS/RTS)

 

&K4

Enable bi-directional software flow control (XON/XOFF)

&Pn

 

Pulse dialing make/break ratio selection

 

&P0

Make=39%, Break=61%, international version (Default)

 

 

Make=33%, Break=67% for use in 20 pps, Japanese version

 

&P1

Make=33%, Break=67%, international version

 

 

Make=33%, Break=67% for use in 10 pps, Japanese version (Default)

&Qn

 

Async communications mode options

 

&Q0

Async mode, buffered (same as “AT\N0”)

 

&Q5 *

Error control mode, buffered (same as “AT\N3”)

 

&Q8

MNP error control mode. If an MNP error control protocol is not

 

 

established, the modem will fallback according to the current setting in

 

 

S36 register.

 

&Q9

V.42 or MNP error control mode. If neither error control protocol is

 

 

established, the modem will fallback according to the current setting in

 

 

S36 register.

&Sn

 

Data Set Ready (DSR) option

 

&S0 *

DSR always on

 

&S1

DSR on during handshake and on-line, off in test mode or idle mode

&Tn

 

Self-test commands

 

&T0

Terminate any test in progress

 

&T1

Local analog loopback test

 

&T3

Local digital loopback (LDL) test

 

&T6

Remote digital loopback test

&V

 

View active file and stored phone numbers

AT Command Set Summaries 15

Page 21
Image 21
ZyXEL Communications 3356P user manual Extended AT& Command Set