30.4 Default DVMRP Timer Values
The following are some default DVMRP timer values.
Table 96 DVMRP: Default Timer Values
DVMRP FIELD DEFAULT VALUE
Probe interval 10 sec
Report interval 35 sec
Route expiration time 140 sec
Prune lifetime Variable (less than two hours)
Prune retransmission time 3 sec with exponential back off
Graft retransmission time 5 sec with exponential back off