Post Error Messages
Numeric Codes and Text Messages
Code/Message | Beeps | Probable Cause | Recommended Action |
None | Hard drive is about to | |
SCSI Hard Drive |
| fail. (Some hard drives |
Detects Imminent |
| have a firmware patch |
Failure |
| that will fix an |
|
| erroneous error |
|
| message). |
1.Determine if hard drive is giving correct error message.
2.Apply firmware patch if applicable.
3.Back up contents and replace hard drive.
None | Hard drive circuitry | 1. Run Computer Setup. | ||
Controller Failure |
| error. | 2. | Clear CMOS. |
|
|
| ||
|
|
| 3. | Check cable seating/jumper |
|
|
|
| settings. |
|
|
| 4. | Run hard drive diagnostics. |
|
|
| 5. | Disconnect additional |
|
|
|
| drives. |
|
|
| 6. | Run the Drive Protection |
|
|
|
| System test if available. |
|
|
| 7. | Check www.compaq.com/ |
|
|
|
| support/techpubs/ |
|
|
|
| customer_advisories/ |
|
|
|
| for possible changes when |
|
|
|
| using Windows NT 4.0 |
|
|
|
| Service Pack 4. |
|
|
| 8. | Replace the hard drive. |
|
|
| 9. | Replace the system board. |
|
|
|
| |
None | Internal temperature | 1. Check that computer air | ||
ture Alert |
| exceeds specification. |
| vents are not blocked and |
|
|
|
| cooling fan is running. |
|
|
| 2. | Verify processor speed |
|
|
|
| selection. |
|
|
| 3. | Replace the processor. |
|
|
| 4. | Replace the system board. |
|
|
|
|
|
Troubleshooting Guide |