Univex SRTZ2401-CA manual Muffler MA6, Spark Arrester, Spark arrester, Intake AIR Cooling Vent

Page 40

English

9. Maintenance

MUFFLER

WARNING

MA6

(1)

Inspect periodically, the muffler for loose fasteners, any damage or corrosion. If any sign of exhaust leakage is found, stop using the machine and have it repaired immediately.

Note that failing to do so may result in the engine catching on fire.

SPARK ARRESTER

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. Periodically inspect and clean as necessary with a wire brush.

In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land. (MA6)

(1) spark arrester

INTAKE AIR COOLING VENT

WARNING

Never touch the cylinder, muffler, or spark plugs with your bare hands immediately after stopping the engine. The engine can become very hot when in operation, and doing so could result in severe burns.

When checking the machine to make sure that it is okay before using it, check the area around the muffler and remove any wood chips or leaves which have attached themselves to the brushcutter. Failing to do so could cause the muffler to become overheated, and that this in turn could cause the engine to catch on fire. Always make sure that the muffler is clean and free of wood chips, leaves, and other waste before use.

Check the intake air cooling vent and the area around the cylinder cooling fins after every 25 hours of use for blockage, and remove any waste which has attached itself to the brushcutter. Note that it is necessary to remove the engine cover shown in (MA7) in order to be able to view the upper part of the cylinder.

40

Image 40
Contents SRTZ2401-CA Information Informationinformación Contents Tables des matieres Contenido Differents Types D’AVERTISSEMENT DE CE Mode D’EMPLOIAdvertencias Contenidas EN EL Manual Specifications Parts locationFiche technique Emplacement des pieces Situación de las piezasEspecificaciohes Symbols on the machine PositionEmplacement PosiciónWorking Condition For safe operationWorking Circumstance Consignes de securite Instrucciones de seguridad Conditions DE TravailCondiciones DE Trabajo PrecaucionesWorking Plan Before Starting the EnginePlan DE Travail Plan DE TrabajoLA Machine Avant DE Mettre LE Moteur EN MarcheUsing the Product Starting the EngineDemarrage DU Moteur Utilisation DE LA MachineArranque DEL Motor USO DEL ProductoMaintenance If Someone ComesSI QUELQU’UN S’APPROCHE SI Alguien SE Aproxima EntretienTout est en ordre de marche MantenimientoRefill after cooling the engine Handling FuelTransportation Manipulation DU Carburant TransportManipulación DEL Combustible Llenar una vez que el motor se haya enfriadoSet up SE1 SE2 Installing HandleAttaching the Trimming Mechanism SE2 Balance UnitAssemblage Montaje Mise EN Place DE LA PoigneeInstalación DEL Mango Equilibrage DE LA MachineFuel When using RedMax/ZENOAH genuine oilRecommended Mixing Ratio Gasoline 50OIL Rapport DE Melange Recommande Essence 50 Huile Carburant CombustibleLors de l’utilisation de la véritable huile RedMax/ZENOAH Proporción DE LA Mezcla Recomendada Gasolina 50 AceiteFueling the Unit HOW to MIX FuelFor Your Engine LIFE, Avoid Comment Obtenir UN BON Melange Como Mezclar EL Combustible Remplissage DU ReservoirEviter Pour Prolonger LA Duree DE VIE DU Moteur Abastecimiento DE LA UnidadFuel Combustible SIN Aceite Gasolina Cruda OP1 OP2 OP3 OP4 Starting Engine OperationCutting head will start rotating upon the engine starts Fonctionnement Uso Palanca del estrangulador 2 cerrarAdjusting Throttle Cable Adjusting Idling Speed OP6OP5 OP6 Stopping Engine OP3Reglage Câble D’ACCÉLÉRATEUR Ajuste Cable DEL AceleradorReglage DU Ralenti OP6 Ajuste DE LA Velocidad DE Marcha EN Vacío OP6OP7 Adjusting the Angle of the Cutting Blades OP7 Clamp bolt Trimming mechanism Tighten LoosenRéglage DE Langle DES Lames Tranchantes OP7 Boulon de serrage Mécanisme de coupe Serrer DesserrerAjuste DEL Ángulo DE LAS Cuchillas DE CORTE. OP7 Perno de sujeción Mecanismo de poda Ajustar AflojarMaintenance Maintenance ChartEntretien MantenimientoTableau D’ENTRETIEN Tabla DE MantenimientoMA1 Blades MA1Quick TIP MA2Entretien Mantenimiento Replacement Plug is a NGK CMR7H MA3 MA4 MA5AIR Filter Fuel FilterFiltre a AIR Filtro DE AireFiltre a Carburant Filtro DE Combustible Bougie D’ALLUMAGE BujíaMuffler MA6 Spark ArresterSpark arrester Intake AIR Cooling VentPARE-ETINCELLES Ouïe DU Refroidissement PAR AIRParachispas Toma DE Aire DE RefrigeraciónProcedures to be Performed After Every 100 Hours of USE StorageDisposal MA7 MA8Procedure a Effectuer Toutes LES 100 Heures D’UTILISATION Rangement AlmacenamientoMise au rebut Eliminación Procedimientos a Realizar Cada 100 Horas DE USO12. Guía de localización y solución de problemas Troubleshooting guideGuide de localisation des pannes Lista de piezas NotaParts list Cutting Unit SRTZ2401/SRTZ2401-CA S/N Z000001 and up Engine Unit SRTZ2401/SRTZ2401-CA S/N 60100101 and up Qty Key# Part Number Description Manufacturer’s warranty coverage Owner’s warranty responsibilitiesCouverture de la garantie constructeur Obligations du propriétaire liées à la garantieCobertura de la garantía dada por el fabricante Responsabilidades del propietarioLimited Warranty Garantie limitée Garantía Limitada Emission Control SRTZ2401Mesures DE Lutte Contre LES Emissions Control DE Emisiones

SRTZ2401-CA, SRTZ2401 specifications

Univex SRTZ2401-CA and SRTZ2401 are advanced refrigeration units designed to meet the rigorous demands of commercial and industrial applications. These models are setting new standards in energy efficiency, reliability, and performance, making them ideal for businesses that require consistent and high-quality cooling solutions.

One of the standout features of the SRTZ2401-CA and SRTZ2401 is the incorporation of cutting-edge cooling technology. They utilize advanced refrigerants which not only comply with the latest environmental regulations but also optimize thermal performance. The units are engineered to provide precise temperature control essential for preserving perishable goods, thanks to their highly responsive digital thermostats that allow users to adjust settings easily.

Durability is another defining characteristic of these refrigeration units. Constructed with high-quality materials, the SRTZ2401 models are designed to withstand the rigors of daily usage in bustling environments. They feature reinforced cabinets that minimize wear and tear while ensuring long-term functionality. Additionally, rust-resistant components prolong their lifespan, offering businesses a reliable cooling solution that operates efficiently over time.

Energy efficiency is a key consideration in today’s market, and the SRTZ2401-CA and SRTZ2401 excel in this aspect. Equipped with energy-saving technologies, these units help businesses reduce their energy consumption and lower operational costs. Their superior insulation helps to maintain consistent internal temperatures, minimizing the need for the compressor to continually cycle on and off. This not only conserves energy but also reduces wear on the system.

Ease of maintenance has also been prioritized in the design of the SRTZ2401 series. The units come with accessible components, allowing for straightforward cleaning and servicing, which is crucial for busy commercial operations. LED indicators and user-friendly interfaces ensure operators can monitor performance quickly and efficiently.

Finally, Univex has committed to customer satisfaction by offering robust support and warranty options, making the SRTZ2401-CA and SRTZ2401 models a dependable choice for any business seeking reliable refrigeration solutions. With their blend of innovative technology, robust construction, and energy efficiency, these units are a smart investment for the future of commercial refrigeration.