Polycom CCUG-0100-01 manual Modem USE with the Vortex, Conference Composer On Site with the Vortex

Page 27

MODEM USE WITH THE VORTEX

MODEM USE WITH THE VORTEX

CONFERENCE

COMPOSER

ON SITE WITH THE VORTEX

You will need Conference Composer version 1.62 or later. You can find the latest version of the software on our website at www.aspi.com, on the Vortex page.

At the local site with the Vortex, use Conference Composer to enable the modem to auto answer:

Figure 19. Modem settings on Conference Composer OPTIONS page.

1.On the OPTIONS page, choose the default initialization string from the INITIAL- IZATION STRING pull-down menu. If a default is not listed, enter the following string:

ATE0F1&B1S0=2

2.Enable the initialization string by clicking on the ENABLE button.

3.Disconnect the RS-232 cable from the Vortex and connect it to your modem. You may need to use a null modem for your modem. Connect your modem to the Vortex.

4.Cycle power on the Vortex. As it powers up, it will send the initialization string to the modem. Make sure the modem is On before cycling power on the Vortex.

If you don’t have Conference Composer on site,

1.Using a terminal program, send the following strings to the Vortex:

F**MINISTRATF1E0&B1S0=2

F**MINI1

This will enter the initialization string and enable it.

2.Disconnect the RS-232 cable from the Vortex and connect it to your modem. You may need to use a null modem for your modem. Connect your modem to the Vortex.

3.Cycle power on the Vortex. As it powers up, it will send the initialization string to the modem. Make sure the modem is On before cycling power.

© Polycom, Inc.

25

Conference Composer User Guide

Image 27
Contents Conference Composer User Guide Page Conference ComposerTM Software Introduction InstallationUsing Conference Composer with a Vortex and EF200 Phone ADD Conference Composertm SoftwareFeatures of the Conference Composer Window Conference Composertm Software Operating Conference Composer OFF-LINE Operating Without AN EF Device Project gen- erated when connected to a VortexOperating Conference Com- poser Offline System Device ParametersOptions Device Name MIC/LINE Inputs Input Filters Automixer EF BUS Exporting the Echo Canceller Reference onMatrix Mixer Device Parameters Outputs Output FiltersLogic Input Logic Output Presets DiagnosticsMacros Creating Reports Project Files and Creating ReportsFile Saving File RestoringConsole TAB Console WindowProperties TAB Updating Firmware Update Your EF DeviceConsole Window Conference Composer On Site with the Vortex Modem USE with the VortexSite From the RemoteVerify That Vortex is Sending Correct Init String Troubleshooting the Vortex Modem Connection