Porter-Cable PC2525SP, D25115-0112-0 Troubleshooting Guide, Problem Cause Correction

Page 18

TROUBLESHOOTING GUIDE

PROBLEM

 

CAUSE

 

CORRECTION

Engine will not

1.

No fuel.

1.

Add Fuel.

start

2.

Pressure builds up after

2.

Squeeze gun trigger to

 

 

 

two pulls on the recoil

 

relieve pressure.

 

 

starter or after initial use.

 

 

 

3.

Not choked.

3.

Choke engine, place

 

 

 

 

engine in the choke posi-

 

 

 

 

tion.

 

4.

Spark plug wire not

4.

Attach spark plug wire.

 

 

attached.

 

 

 

5.

Choke lever in the

5.

Move choke to the "No

 

 

"Choke" position on a

 

Choke" position.

 

 

"hot" engine or an engine

 

 

 

 

that has been exposed to

 

 

 

 

thermal heat for a long

 

 

 

 

period of time.

 

 

 

6.

Fuel valve closed

6.

Move the fuel valve knob

 

 

 

 

to the "Open" position.

 

 

 

 

 

No or low

1.

Wand not in high pres-

1.

See How to Use Wand

pressure

 

sure.

 

paragraph in the

(initial use)

 

 

 

Operation Section.

 

 

 

 

 

2.

Low water supply.

2.

Water supply must be at

 

 

 

 

least 5 GPM @ 20 PSI.

 

3.

Leak at high pressure

3.

Repair leak. Apply sealant

 

 

hose.

 

tape if necessary.

 

4.

Nozzle obstructed.

4.

Clean nozzle with paper

 

 

 

 

clip or nozzle cleaning

 

 

 

 

tool, pour water into noz-

 

 

 

 

zle end to flush out ob-

 

 

 

 

struction.

 

5.

Water filter screen

5.

Remove and clean filter.

 

 

clogged.

 

 

 

 

 

 

 

D25115

18- ENG

Image 18
Contents Horsepower 2500 PSI GPM Pressure Washer Maintenance Instructions General InformationTo 600 p.m. C.S.T Hazard Safety Guidelines DefinitionsImportant Safety Instructions Risk of Explosion or FireRisk of Explosion or Fire Risk to BreathingRisk of Unsafe Operation Risk of Electrical ShockRisk to Fluid Injection Risk of Chemical BurnRisk of HOT Surfaces Arrival at your destinationBOX Contents Assembly Engine OperationPressure Washer Pressure Washer TerminologyTo Adjust Pressure To USE WandENG To Siphon CHEMICALS/CLEANING Solvents To Shut DownBefore Starting Filter Screen Maintenance Pump WandStorage Peratures are ExpectedTroubleshooting Guide Problem Cause CorrectionIs a steady stream Oil leaking at PumpENG Limited Warranty Responsibility of Original Purchaser initial User