WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a
SUNNY | PARTLY | CLOUDY | RAINY |
| CLOUDY |
|
|
|
|
|
|
TEMPERATURE
This product can display current, minimum, and maximum temperature information collected by the remote sensors and main (indoor) unit.
Outdoor data is collected and displayed every 40 seconds. Indoor data is collected and displayed every 10 seconds.
SELECT TEMPERATURE UNIT
Slide the °C / °F switch into the desired location. The switch is located in the main unit battery compartment. The setting for the main unit overrides the remote sensor setting.
SELECT CHANNEL NUMBER
Press CHANNEL to switch between sensors
The icon shows the selected sensor.
|
|
|
| |
ICON |
|
|
|
|
|
|
|
|
|
DESIGNATED | Indoor | Remote | Remote | Remote |
DISPLAY | Display | Display | Display | Display |
|
| Channel 1 | Channel 2 | Channel 3 |
|
|
|
|
|
To
NOTE For more information on the sensor see "Remote Sensor THN122N" section.
MINIMUM / MAXIMUM RECORDS
The MEMORY button is located in the main unit battery compartment. Press MEMORY to toggle between current, maximum (MAX) and minimum (MIN) records. To clear the records, press and hold MEMORY for 2 seconds. A beep will sound to confirm that the memory has been cleared.
MOON PHASE
The Calendar must be set for this feature to work, see "Set Clock" section.
•Press or to view the moon phase for the next or previous day.
•Press and hold or to scan quickly through the years (2001 to 2099).
New Moon
Waxing Crescent
First Quarter
Waxing Gibbous
Full Moon
Waning Gibbous
Last Quarter
Waning Crescent
BACKLIGHT
Press LIGHT to activate the backlight for 8 seconds.
RESET SYSTEM
The RESET button is located in the main unit battery compartment. Press RESET when you change the batteries and whenever performance is not behaving as expected (for example, unable to establish radio frequency link with remote sensor or atomic clock).
SAFETY AND CARE
Clean the product with a slightly damp cloth and alcohol- free, mild detergent. Avoid dropping the product or placing it in a
WARNINGS
This product is designed to give you years of service if handled properly. Oregon Scientific will not be responsible for any deviations in the usage of the device from those specified in the user instructions or any unapproved alterations or repairs of the product. Observe the following guidelines:
•Never immerse the product in water. This can cause electrical shock and damage the product.
•Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity.
•Do not tamper with the internal components.
•Do not mix new and old batteries or batteries of different types.
•Do not use rechargeable batteries with this product.
•Remove the batteries if storing this product for a long period of time.
•Do not scratch the LCD display.
NOTE The technical specification of this product and contents of this user guide are subject to change without notice. Images not drawn to scale.
TROUBLESHOOTING
PROBLEM | SYMPTOM | REMEDY | |
|
|
| |
Calendar | Strange date / | Change language | |
| month |
| |
|
|
| |
Clock | Cannot adjust | Disable atomic clock | |
| clock |
| |
|
|
| |
| Cannot auto- | 1. Adjust batteries | |
| synchronize the | 2. Press RESET | |
| date and time | 3. Manually activate | |
|
| atomic feature | |
|
|
| |
Temp | Shows "LLL" or " | Temperature is | |
| HHH" | ||
|
|
| |
Remote | Cannot locate | Check batteries | |
sensor | remote sensor |
| |
Check location | |||
|
| ||
|
|
| |
| Cannot change | Check sensors. | |
| channel | Only one sensor is | |
|
| working | |
|
|
| |
| Data does not | Initiate a manual | |
| match main unit | sensor search | |
|
|
|
SPECIFICATIONS
MAIN UNIT DIMENSIONS
| L x W x H | 2.7 x 1.7 x 5.6 inches |
|
| (68.8 x 44.4 x 141.7 mm) |
| Weight | 4.9 ounces (138 g ) without |
|
| battery |
|
| |
| REMOTE SENSOR DIMENSIONS | |
| L x W x H | 3.6 x 2.4 x 0.79 inches |
|
| (92 x 60 x 20 mm) |
| Weight | 2.22 ounces (63 grams ) |
|
| without battery |
|
|
|
| TEMPERATURE |
|
| Unit | °F / °C |
| Indoor range | 23°F to 122°F |
|
| |
| Outdoor range | |
|
| |
| Resolution | 0.2°F (0.1°C) |
|
|
|
| WEATHER FORECAST |
|
| Display | Rainy, cloudy, partly |
|
| cloudy, sunny |
|
| |
| REMOTE SENSOR (THN122N) | |
| RF frequency | 433 MHz |
| Range | 98 feet (30 meters) with no |
|
| obstructions |
| Transmission | Every 40 seconds |
| Channel No. | |
|
|
|
| CLOCK |
|
| Atomic Clock | Auto or manual (disabled) |
| Clock display | HH:MM:SS |
| Hour format | 12hr AM / PM |
|
| (Model BAR636A) |
| Calendar | MM / DD; weekday in |
|
| 5 languages (E, D, F, I, S) |
| Alarm | Single alarm with |
|
| |
|
| |
|
|
|
| POWER |
|
| Main unit batteries | 3 x |
| Sensor batteries | 2 x |
NOTE It is recommended that you use alkaline batteries with this product for longer performance.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children’s electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our Customer Care department in case you need to reach us, as well as frequently asked questions and customer downloads.
We hope you will find all the information you need on our website, however if you’re in the US and would like to contact the Oregon Scientific Customer Care department directly, please visit: www2.oregonscientific.com/service/support
OR
Call
For international inquiries, please visit: www2.oregonscientific.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead.
We |
|
Name: | Oregon Scientific, Inc. |
Address: | 19861 SW 95th Ave., |
| Tualatin, Oregon 97062 USA |
Telephone No.: | |
Fax No.: | |
declare that the product |
|
Product No.: | BAR636A |
Product Name: | Weather Station |
Manufacturer: | IDT Technology Limited |
Address: | Block C, 9/F, Kaiser Estate, |
| Phase 1,41 Man Yue St., |
| Hung Hom, Kowloon, |
| Hong Kong |
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
©2005 Oregon Scientific. All rights reserved. P/N.:
BAR636A_M_EN_V2.p65 | 2 | 2005.7.1, 9:44 AM |