Omega 8000 owner manual Ground Error

Page 17

GROUND ERROR cont.

*When the detector’s internal Ground Setting is higher than the actual phase of the ground, the bars on the top of the graph will be illuminated. The bigger the error is, the more bars will show up.

*When the detector’s internal Ground Setting is lower than the actual phase of the ground, the bars on the bottom of the graph will be illumi- nated. The bigger the error is, the more bars will show up.

*If the Ground Error exceeds the level of three bars, or will appear, indicating that the maximum error has been reached, and action must be taken to adjust the Ground Setting.

To maintain maximum detector performance, keep the Ground Error to a mini- mum by adjusting the Ground Setting.

Before making an adjustment, it is best to verify the Ground Error as follows:

1.Place the detector into AutoTune Mode.

2.Pump the searchcoil up and down over a patch of ground free of metal, repeatedly moving the coil to within 2” of the ground and lifting it up about 6” over the ground.

If bars appear at the top of the graph, adjust the Ground Setting by pressing the until all of the bars disappear. If bars appear at the bottom of the graph, adjust the Ground Setting by pressing the until all of the bars disappear.

While in AutoTune Mode, pumping the searchcoil over the ground, you will also hear audible evidence of an out-of-adjustment Ground Setting. If the Ground Setting is too low, there will be a difference in the sound as the searchcoil is moving away from the gound. It will sound like you are pulling the sound out of the ground. If the Grown setting is too high, it will sound like you are pushing the sound into the ground.

If the sound is louder as you raise the searchcoil, press to increase the ground balance setting.

If the sound is louder as you lower the searchcoil, press reduce the ground balance setting.

17

Image 17
Contents Off appliances and lights Metal DetectorTable of Contents Metals which are made of, or contain, iron TerminologyAssembly is easy and requires no tools AssemblyDetector can also be used without the strap, with no Adjusting the Arm RestSpeaker Volume and Battery Charge Battery LifeBattery Indicator Segments Illuminated Battery VoltageSupplies Needed QUICK-START DemonstrationII. Position the Detector Wave each object over the searchcoil Bas Tone Nail Low ToneIX. Wave the nickel QUICK-STARTPress the Notch touchpad on the front panel three times XI. Wave the NickelIdentifying Buried Objects Ground MineralsTrash Basics Use with headphones not includedSize and Depth of Buried Objects Electromagnetic Interference EMIOperation and Controls Powering UPSensitivity Control PanelDisc / AT Autotune DiscriminationFreq Frequency Selection Control PanelGND Grab Ground Grab Notch Selective Target Inclusion or Exclusion Tones Number of Tones SelectionWhy do I need to Ground Balance? What is Ground BALANCING?How to Ground Balance your detector Ground BalancingFe 3O Ground ErrorGround Error Varying in proportion to target Ground Adjustment ChartDime Dimes and pre-1982 copper pennies will register here Depth and Target DisplaySmall gold items will register under Iron or Foil Typical Value Possible Objects Pinpointing process in motion modes Search Techniques in Disc modeNarrow It Down Target Pinpointing in Pinpoint modePinpoint as follows Unit Specifications Year Limited Warranty