SECTION 1: HEATER SAFETY

SECTION 2: INSTALLER RESPONSIBILITY

The installer is responsible for the following:

To install the heater, as well as the gas and electrical supplies, in accordance with applicable specifications and codes. Roberts-Gordon recommends the installer contact a Local Building Inspector or Fire Marshal for guidance.

To use the information given in a layout drawing and in the manual together with the cited codes and regulations to perform the installation.

To install the heater in accordance with the clearances to combustibles.

To furnish all needed materials not furnished as standard equipment.

To plan location of supports, vents and air intakes.

To provide access for servicing.

To provide the owner with a copy of this Installation, Operation and Service Manual.

To never use heater as support for a ladder or other access equipment and never hang or suspend anything from heater.

To ensure there is adequate air circulation around the heater and to supply air for combustion, ventilation and distribution in accordance with local codes.

2.1 Wall Tag

A laminated wall tag is included with the heater as a permanent reminder of the safety instructions and the importance of the required clearances to combustibles. Affix the tag by peeling off the backing of the adhesive strips on the rear surface and position the tag on a wall near the heater.

A copy of the wall tag (P/N 91040031) is illustrated on the back cover.

Know your model number. Model number is found on the heater and throughout the Installation, Operation and Service Manual.

2.2 Corrosive Chemicals

Caution: Do not use heater in an area containing corrosive chemicals. Avoid the use of corrosive chemicals to ensure a longer life of the burner, heat exchanger and other parts.

Roberts-Gordon cannot be responsible for ensuring that all appropriate safety measures are undertaken prior to installation; this is entirely the responsibility of the installer. It is essential that the contractor, the sub-contractor, or the owner identifies the presence

of combustible materials, corrosive chemicals or halogenated hydrocarbons* anywhere in the premises.

*Halogenated Hydrocarbons are a family of chemical compounds characterized by the presence of halogen ele- ments (fluorine, chlorine, bromine, etc.). These compounds are frequently used in refrigerants, cleaning agents, solvents, etc. If these compounds enter the air supply of the burner, the life span of the heater components will be greatly reduced. An out- side air supply must be provided to the burners whenever the presence of these compounds is suspected. Warranty will be invalid if the heater is exposed to halogenated hydrocarbons.

2.3 National Standards and Applicable Codes

All appliances must be installed in accordance with the latest revision of the applicable standards and national codes. This refers also to the electric, gas and venting installation. Note: Additional standards for installations in public garages, aircraft hangars, etc. may be applicable.

5

Image 11
Contents Blackheat Page Roberts-Gordon LLC Page Table of Figures Page Safety Labels and Their Placement Heater SafetyManpower Requirements UHA 30 45 Label Placement UHA 60 75 Label Placement UHA 100 125 Label Placement National Standards and Applicable Codes Installer ResponsibilityWall Tag Corrosive ChemicalsClearances to Combustibles Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information Manufactured UnitsVent Gas SupplyElectrical Supply National Standards and Applicable Codes High Altitude Wall Mounting Major Components 5.1 GeneralShelf Mounting and Suspension Suspension Methods Wall Shelf Mounting and Hanging Suspension Vertical Louvers Optional United States Requirements Vent InstallationVenting Changing Vent and Air Intake OrientationHorizontal Venting Standard Vented Heaters Models Uhax 30Separated Combustion Heaters Models Uhaxs 30 Unvented OperationVent Material Vertical VentingLength Requirements Maximum Vent LengthsVent and Roof Detail Standard Vented Heater Common Vertical Vent Termination Concentric Vent Box Vertical Building Ventilation Separated Combustion InstallationUnvented Installation AIR SupplyConnections GAS PipingLow Voltage Thermostat with One Heater WiringPositioning Thermostats Fan ControlLow Voltage Thermostat with Multiple Heaters 30 Low Voltage Thermostat with Multiple Heaters 60 Transformer Internal Wiring DiagramFlame Ladder Wiring DiagramElectrical Connection to the Heater Operation and Maintenance Pressure Regulator Gas Outlet Outlet Pressure Turning Off the Heater Pressure SwitchCheck Gas Rate Instruction to the User Complete Start-UpLighting Instructions 11.4.1 To Turn On Heater User InstructionsUser Instructions Heater OperationTo Turn the Heater Off Simple TroubleshootingSimple Troubleshooting Burner Faults Servicing Vehicles and Other Maintenance ChecklistVenting and Air Intake Pipe Vicinity of the HeaterHeat Exchanger When installed Wall TagCombustion Air Intake PipeTroubleshooting 13.1 General Conduct start-up procedure as shown on Page 29, Section Troubleshooting For Automatic Ignition Burner SystemsTroubleshooting for Flame Supervision System Troubleshooting for Flue Blower Troubleshooting for Gas ValvesBurner Components Replacement PartsBurner Injectors Burner CompartmentIgnition Electrode and Flame Probe Re-used Louver and Louver SpringsFlue Blower Vertical Installation Ignition Control Axial Fan/Guard/Motor AssemblyLimit Switches Removal and Replacement Fan Removal and ReplacementTo Replace the Fan Assembly Model Uhaxs Specifications 15.1 Dimension DataTechnical Data Table All Models General Technical Data Table All ModelsLimitations on Authority Representatives Warranty is Void ifRoberts Gordon will not PAY for Roberts-GordonPage Owner Warranty Registration Card Page Page Some objects can catch fire or explode when placed
Related manuals
Manual 60 pages 21.77 Kb

60, 30, 45, 125, 100 specifications

Roberts Gordon is a recognized leader in the manufacturing of innovative heating solutions, with a diverse product line including the 100, 125, 75, 45, and 60 series of radiant tube heaters. Each model is designed to meet specific heating needs while emphasizing efficiency, durability, and performance.

The Robert Gordon 100 series is known for its high efficiency and ability to provide consistent warmth in large industrial spaces. It features advanced infrared technology, which heats objects and surfaces directly, resulting in quicker temperature increases and enhanced comfort. This model is equipped with modulating burners that allow for optimal gas usage and can be easily integrated into existing systems.

The 125 series builds upon the efficiency of the 100 model while offering increased heating capacity. Its robust design ensures it can handle the demands of larger applications, such as warehouses and manufacturing facilities. With enhanced control options, users can tailor the heating output to match specific operational requirements, reducing energy consumption.

The 75 series offers a compact solution for smaller commercial spaces, providing a reliable heating source without taking up excessive floor space. Its lightweight design facilitates easy installation, while the modular approach allows for scalability to meet changing heating demands. This series emphasizes sustainability, utilizing advanced combustion technologies that minimize emissions.

For smaller applications, the 45 series stands out with its efficient heating capabilities in confined spaces. This series features simple, yet effective controls, enabling straightforward operation. The robust construction ensures durability, making it well-suited for different commercial environments, including retail settings or small workshops.

Finally, the 60 series combines the best features of the range with energy conservation as a primary focus. Its innovative design incorporates smart technology to monitor energy usage and optimize performance. The heaters are equipped with the latest in safety features, providing peace of mind for users.

Overall, Roberts Gordon’s radiant tube heaters showcase a commitment to high-quality heating solutions that cater to a variety of industrial and commercial applications. With energy efficiency, superior durability, and advanced heating technologies as core characteristics, Roberts Gordon remains a trusted choice for businesses looking to enhance their heating performance.