Roberts Gorden 60, 75, 100, 125, 45, 30 service manual Owner Warranty Registration Card

Page 59

W a r m

®

A i r H e a t i n g

OWNER WARRANTY REGISTRATION CARD

Mail or Fax to:

Roberts Gordon LLC • 1250 William Street, P.O. Box 44 • Buffalo, NY 14240-0044 • Phone: 716-852-4400 • Fax: 716-852-0854

Toll Free: 800-828-7450www.rg-inc.com

About the Owner:

Name:__________________________________________________________________________________________________

Address:______________________________________City:_________________________State:__________Zip Code:________

Phone:_________________________ Fax:_________________________ E-mail:______________________________________

About the Installer:

Name:__________________________________________________________________________________________________

Address:______________________________________City:_________________________State:_________Zip Code:_________

Phone:__________________________Fax:_________________________E-mail:______________________________________

Purchased From (if different than installer):

Name:__________________________________________________________________________________________________

Address:______________________________________City:_________________________State:__________Zip Code:________

Phone:_________________________ Fax:_________________________ E-mail:______________________________________

About your Heater:

Model#:_______________________ Serial #:___________________________ Fuel:____________ Installation Date:__________

Type of Installation (check one):

o

Automotive

o

Manufacturing

o

Warehouse

o

Recreational

o

Aircraft

o

Public Building

o

Office

o

Retail

o

Agricultural

o

Other______________

Installation Code and Annual Inspections: All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and service of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals and all applicable governmental authorities pertaining to the installation, service and operation of the equipment.

To help facilitate optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON® equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon.

These products are not approved for residential use, except for models UHA[X][S] 30 - UHA[X][S] 75.

©2008 Roberts-Gordon LLC - All rights reserved. No part of this work covered by the copyrights herein my be reproduced or copied in any form or by any means – graphic, electronic, or mechanical, including photcopying, recording, taping, or information storage and retrieval systems – without written permission of Roberts Gordon LLC.

Printed in the U.S.A.

Image 59
Contents Blackheat Page Roberts-Gordon LLC Page Table of Figures Page Safety Labels and Their Placement Heater SafetyManpower Requirements UHA 30 45 Label Placement UHA 60 75 Label Placement UHA 100 125 Label Placement National Standards and Applicable Codes Installer ResponsibilityWall Tag Corrosive ChemicalsClearances to Combustibles Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information Manufactured UnitsVent Gas SupplyElectrical Supply National Standards and Applicable Codes High Altitude Wall Mounting Major Components 5.1 GeneralShelf Mounting and Suspension Suspension Methods Wall Shelf Mounting and Hanging Suspension Vertical Louvers Optional United States Requirements Vent InstallationVenting Changing Vent and Air Intake OrientationHorizontal Venting Standard Vented Heaters Models Uhax 30Separated Combustion Heaters Models Uhaxs 30 Unvented OperationVent Material Vertical VentingLength Requirements Maximum Vent LengthsVent and Roof Detail Standard Vented Heater Common Vertical Vent Termination Concentric Vent Box Vertical Building Ventilation Separated Combustion InstallationUnvented Installation AIR SupplyConnections GAS PipingLow Voltage Thermostat with One Heater WiringPositioning Thermostats Fan ControlLow Voltage Thermostat with Multiple Heaters 30 Low Voltage Thermostat with Multiple Heaters 60 Transformer Internal Wiring DiagramFlame Ladder Wiring DiagramElectrical Connection to the Heater Operation and Maintenance Pressure Regulator Gas Outlet Outlet Pressure Turning Off the Heater Pressure SwitchCheck Gas Rate Instruction to the User Complete Start-UpLighting Instructions 11.4.1 To Turn On Heater User InstructionsUser Instructions Heater OperationTo Turn the Heater Off Simple TroubleshootingSimple Troubleshooting Burner Faults Servicing Vehicles and Other Maintenance ChecklistVenting and Air Intake Pipe Vicinity of the HeaterHeat Exchanger When installed Wall TagCombustion Air Intake PipeTroubleshooting 13.1 General Conduct start-up procedure as shown on Page 29, Section Troubleshooting For Automatic Ignition Burner SystemsTroubleshooting for Flame Supervision System Troubleshooting for Flue Blower Troubleshooting for Gas ValvesBurner Components Replacement PartsBurner Injectors Burner CompartmentIgnition Electrode and Flame Probe Re-used Louver and Louver SpringsFlue Blower Vertical Installation Ignition Control Axial Fan/Guard/Motor AssemblyLimit Switches Removal and Replacement Fan Removal and ReplacementTo Replace the Fan Assembly Model Uhaxs Specifications 15.1 Dimension DataTechnical Data Table All Models General Technical Data Table All ModelsLimitations on Authority Representatives Warranty is Void ifRoberts Gordon will not PAY for Roberts-GordonPage Owner Warranty Registration Card Page Page Some objects can catch fire or explode when placed
Related manuals
Manual 60 pages 21.77 Kb

60, 30, 45, 125, 100 specifications

Roberts Gordon is a recognized leader in the manufacturing of innovative heating solutions, with a diverse product line including the 100, 125, 75, 45, and 60 series of radiant tube heaters. Each model is designed to meet specific heating needs while emphasizing efficiency, durability, and performance.

The Robert Gordon 100 series is known for its high efficiency and ability to provide consistent warmth in large industrial spaces. It features advanced infrared technology, which heats objects and surfaces directly, resulting in quicker temperature increases and enhanced comfort. This model is equipped with modulating burners that allow for optimal gas usage and can be easily integrated into existing systems.

The 125 series builds upon the efficiency of the 100 model while offering increased heating capacity. Its robust design ensures it can handle the demands of larger applications, such as warehouses and manufacturing facilities. With enhanced control options, users can tailor the heating output to match specific operational requirements, reducing energy consumption.

The 75 series offers a compact solution for smaller commercial spaces, providing a reliable heating source without taking up excessive floor space. Its lightweight design facilitates easy installation, while the modular approach allows for scalability to meet changing heating demands. This series emphasizes sustainability, utilizing advanced combustion technologies that minimize emissions.

For smaller applications, the 45 series stands out with its efficient heating capabilities in confined spaces. This series features simple, yet effective controls, enabling straightforward operation. The robust construction ensures durability, making it well-suited for different commercial environments, including retail settings or small workshops.

Finally, the 60 series combines the best features of the range with energy conservation as a primary focus. Its innovative design incorporates smart technology to monitor energy usage and optimize performance. The heaters are equipped with the latest in safety features, providing peace of mind for users.

Overall, Roberts Gordon’s radiant tube heaters showcase a commitment to high-quality heating solutions that cater to a variety of industrial and commercial applications. With energy efficiency, superior durability, and advanced heating technologies as core characteristics, Roberts Gordon remains a trusted choice for businesses looking to enhance their heating performance.