OUTPUTS

(T1,T2)

 

P IMPEDANCE

1.405Ω

P SLEW RATE

> 2.5A/∝s

P OVERSHOOT

< 100mA + 10% of pulse amplitude

P AMPLITUDE

0-25A (loads 1 - 10 ohm)

P PEAK CURRENT

25A per channel

P DC CURRENT LIMIT

150mA (each channel)

COMPUTER INTERFACE

P RS232

9600 Baud. All instrument functions and settings may

 

be controlled over the interface bus.

GENERAL

P STORAGE

Twelve (12) complete configurations may be stored

 

and recalled from the front panel or the computer

 

interface.

P WEIGHT

10 lbs.

P POWER

< 100W @ 120 or 220VAC

20

Image 24
Contents Series Pulse Generator Table of Contents Mode Pulse Modes External Trigger Mode Single Shot Mode Iii Parts List WarrantyIntroduction Technical SupportSafety Issues Custom ModificationsPage Page Controls and Connectors Front PanelDisplay Control ButtonsLeft Button Output SectionsRear Panel External TriggerSync Out InterlockGpib Port optional AC InputOperating Instructions OverviewNumeric Input Mode Item Edit ModeMode Pulse Modes Main MenuEnable TnEnable NDly Tn DelayChannel Menus NIamps TnIampsStore Configuration Recall ConfigurationStore/Recall/Misc. Menus NWid TnPulse WidthVolume Shot CounterFmark GPIBAddr optionalPage Command Language Serial RS232 PinoutCommand Protocol OkcrlfCommunication Protocol Command List Communication CommandsSpecifications DelaysOutputs Maintenance Replacing the FusePage Custom Features Long Pulse Option Specifications