OPERATION
STARTING AND STOPPING
See Figures 21 - 22.
Trimmer should be on a flat, bare surface for starting. The starting method differs depending on whether the engine is cold or warm.
To start a cold engine:
Slowly press the primer bulb seven (7) times.
Rotate the choke dial clockwise to the FULL CHOKE position.
Squeeze throttle trigger fully and continue to hold through remaining steps.
Pull the starter grip sharply until engine attempts to run (no more than 4 pulls).
Rotate the choke dial counterclockwise to the HALF CHOKE position.
Pull the starter grip sharply until the engine runs.
Allow the engine to run for 10 seconds.
Rotate the choke dial counterclockwise to the RUN position.
To start a warm engine:
Slowly press the primer bulb seven (7) times.
Pull the starter grip sharply until the engine runs.
TO STOP THE ENGINE:
See Figure 21.
Release the throttle trigger and press and hold STOP on the engine switch.
IF ASSISTANCE IS REQUIRED STARTING THIS PRODUCT:
Do not return this product to the retail store where it was purchased. Please call our Customer Service Department for any issues you may have.
For Help Call: 1-800-860-4050
PRIMER
STARTER BULB GRIP
CHOKE DIAL
STARTER
SWITCH
THROTTLE
TRIGGER
Fig. 21
PRIMER BULB
FULL
CHOKE
HALF
CHOKE
RUN
Fig. 22