Acu-Rite 00614/00626SB instruction manual Calibration option

Page 16

00614 Calibration option

2.

Insert a small nut 6-32 hex nut into the base receiver (stainless steel) is preferred -secure the nut in place using glue or silicone caulk

-install a screw 6-32 into the nut, 3/4” or 1” long should work best.

Remove (un-snap) this part

1. It will not be used when the rain gauge is set up to be calibrated

Height mark

3.Use the original plastic stop as a height gauge turn it upside down as shown in the picture.

This will provide the initial screw height.

---Raising the height of the screw increases the rain fall reading by allowing the bucket to tip sooner, with a smaller volume of water

---lowering the height of the screw decreases the rain fall reading

*** every bucket tip equals 0.02” of rainfall

Image 16
Contents Overview of Features Main Unit Please do not return product to the retail storeOverview of Features Rain Collector Install BatteriesSetup Placement of Main Unit Placement of Rain CollectorPlacement Surface Mounting of Rain CollectorCare Instructions for Rain Collector Wireless ReceptionOperation Troubleshooting Set Wireless IDSpecifications Product SpecificationsCaracterísticas Generales Unidad Principal Garantía Limitada POR UN AÑOInstalación de las baterías Características Generales DEL Colector DE Lluvia InstalaciónUbicación de la unidad principal Ubicación del colector de lluviaSuperficie de montaje del colector de lluviaDEL Suelo UbicaciónRecepción inalámbrica Instrucciones para el cuidado del colector de lluviaFuncionamiento Especificaciones Rangos de mediciónEspecificaciones DEL Producto Page Page Page Page Page Calibration option