Baldor ID101F50-E manual Keypad Status Indicator, Status Indication Operating Condition

Page 38

Arrow is also used to decrement the set speed in the Stop Mode and decrement the actual speed in the Run Mode. The value will decrease at a faster rate after holding the DOWN Arrow key for 5 seconds. Pressing SHIFT while holding the DOWN Arrow will bypass the 5 second delay.

ENTER Used to store a new parameter value when in the Programming Mode. Also used in the Run and Stop Modes to store the current output frequency as the initial output frequency when power is applied to the inverter.

Keypad Status Indicator

The STATUS indicator consists of two LED's, one green and one red. They are visible through a lens in the upper right hand corner of the keypad. The following table defines the STATUS indicator state for the various operating conditions of the inverter.

STATUS INDICATION

OPERATING CONDITION

 

Continuous displays

Green and Red

 

Power on, Restart (2 Seconds)

Red

 

Stop, Running in Torque Limit

Green

 

Run

 

 

Intermittent Displays

Alternate Green and

 

Running in and out of Torque Limit

Red Blinking

 

 

 

 

 

Green Blinking

 

Running in and out of an Overvoltage

 

 

or Undervoltage condition

Red Blinking

 

Fault Condition, Emergency Stop,

 

 

Auto Restart Lock-out, Low Voltage

Operation 3-3

Image 38
Contents Series Inverter Control Installation and Operating Manual MN710Table of Contents Level One Parameter Adjustments Min Output Frequency Appendix a Limited Warranty Section General InformationSafety Notice General Information Specifications NemaElectronic Potentiometer Analog Outputs Fault ConditionsOperator Keypad Relay OutputsAmps Volts RatingsCatalog No Input Output General Information Section Installation Location and MountingTerminal Access Cover Removal Wiring Considerations Terminal and Jumper LocationsInstallation Rated Input Input Fuses Catalog No Wire Size and Protection DevicesBreaker Fast Time AWG Cu Acting Delay Main Circuit Wiring AC Power Connections Motor Connections Contactor Typical Connections for M-ContactorLogic Wiring Analog Command InputsExternal Trip Connection Analog OutputOpto Isolated Inputs Jumper J19 Input Selection Jumper J19 SelectionsSelection Of Operation Mode And Connection Diagrams Function Wire Run/Stop ConnectionsSpeed Select PS2 PS1 Ramp SelectParameter 21 Operating Mode = 4 or Wire Run/Stop, Electronic Potentiometer Connections Parameter 21 Operating Mode =Relay Output MOL Terminal Connections 77-External Trip SelectAnalog Meter Installation Check of Motors/Couplings Pre-Operation ChecksCheck of Electrical Items Temporary Application of Power Pre-Operation Check ListInstallation Section Operation Keypad Key FunctionsOperation Keypad Status Indicator Status Indication Operating ConditionDescription of Keypad Displays Run Mode Symbol DescriptionStop Mode Security Access/Lockout Control Operation AdjustmentProgram Mode Level One Parameter Adjustments Parameter 21-Operating Mode Value Start Control Type of ControlCommand Control Terminals Description FWD REV PS1 PS2 Operation Operation Parameter 71-ANALOG Output Select Level Two Parameter Adjustments Parameter 75-RELAY Output Select Value DescriptionOperation Operation Parameter 41-ACCEL/DECEL/COAST Select Value Description Operation Braking Action / Function DC Braking Disabled Parameter 41-Parameter 47-DC Brake Time50% Square Volts/Hertz ProfilesLinear LawOperation Operation Parameter 77-External Trip Select Description / FunctionParameter 81-Factory Settings Value Description Parameter 82-Start Options Value Description Command is given at the Control Terminal Strip Operation Section Troubleshooting Diagnostic DisplaysFault Codes Fault Code Description Indication Possible Cause Corrective Action MaintenanceTroubleshooting Motor overloadedOverload AdjustedSpeeds Input voltage too high Troubleshooting Illustrations Illustrations HP Nema 230 & 460VAC Illustrations Appendix a Parameters Parameter ListParam Parameter Description Adj Factory User Range Setting Parameter List ± Baldor Electric Company MN710 98 C&J2500 Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792Form 1099A

ID101F50-E specifications

The Baldor ID101F50-E is an advanced industrial electric motor designed for a variety of heavy-duty applications. Known for its robust construction and high efficiency, this motor is a preferred choice in manufacturing, conveyor systems, and automated machinery where reliability and performance are critical.

One of the primary features of the ID101F50-E is its outstanding efficiency rating. With high efficiency levels, it helps reduce energy consumption, which not only lowers operating costs but also aligns with modern demands for sustainability in industrial practices. The motor's efficiency contributes to a reduced carbon footprint, making it a more environmentally friendly option.

Another significant characteristic of the Baldor ID101F50-E is its high power output. This motor can deliver substantial torque, making it suitable for applications requiring heavy lifting and durable operation. Its design allows for continuous operation at high loads without overheating, which is essential for industries that rely on uninterrupted functionality.

In terms of construction, the ID101F50-E is built with high-quality materials that ensure durability and longevity. The robust housing and premium internal components assist in protecting the motor from harsh environmental conditions, making it well-suited for demanding industrial environments. Its rugged construction means it can withstand vibration, extreme temperatures, and exposure to contaminants.

The motor also incorporates advanced technologies that enhance its performance. For instance, it employs precision engineering techniques in its rotor and stator designs, which minimize losses during operation. This contributes to its overall high performance and reliability. Additionally, the ID101F50-E features advanced cooling mechanisms to maintain optimal operating temperatures, ensuring stability and longevity.

Further enhancing its usability, the Baldor ID101F50-E is designed for easy installation and maintenance. Its standard mounting configurations allow for straightforward integration into existing systems. Maintenance access is simplified, which reduces downtime and helps keep production schedules on track.

In conclusion, the Baldor ID101F50-E is a powerful electric motor that strikes an excellent balance between performance, efficiency, and durability. Its high efficiency, significant power output, robust construction, and advanced technologies make it an ideal choice for various industrial applications, standing as a testament to Baldor's commitment to innovation and quality in electric motor design.