Baldor ID101F50-E manual Operation

Page 61
+ 600

Frequency), a setting of ª1º will display Output Current (parameter 14-Output Current), and a setting of ª2º will display Drive Load (parameter 15-Drive Load). A setting of 3-3000 will display RPM. To display an exact RPM number for a given motor rated speed, the value of Display Options is found by the following formula:

Value Displayed

20

(Output Frequency) + Display Option Value

For Example: To display 1800 RPM at 60 Hz use 600 as the Display Option value:

1800 20

60

87-Security Access Code - Sets if a security code will need to be entered before any parameter can be modified. If the Security State is active a security code will need to be entered before parameter changes can be made from the keypad. Setting the Security Access Code to ª0º will defeat the security system. In any case the user will have the ability to view the parameter values. Access is allowed for ten minutes after the last keystroke or until the control goes through a restart sequence. Press the PROG key twice within two seconds after programming to immediately reinstate the access code. The security access code can be set from any number between 001 and 999. When changing the Security Access Code parameter the old Access Code will not be displayed. The factory setting is 0.

Note: Please write down your chosen Security Access Code in a secure location. If you cannot gain entry into the security area to change a parameter, please contact BALDOR.

3-26 Operation

Image 61
Contents MN710 Series Inverter Control Installation and Operating ManualTable of Contents Level One Parameter Adjustments Min Output Frequency Appendix a Section General Information Limited WarrantySafety Notice General Information Nema SpecificationsElectronic Potentiometer Operator Keypad Fault ConditionsAnalog Outputs Relay OutputsCatalog No Input Output RatingsAmps Volts General Information Location and Mounting Section InstallationTerminal Access Cover Removal Terminal and Jumper Locations Wiring ConsiderationsInstallation Breaker Fast Time AWG Cu Acting Delay Wire Size and Protection DevicesRated Input Input Fuses Catalog No Main Circuit Wiring AC Power Connections Motor Connections Typical Connections for M-Contactor ContactorAnalog Command Inputs Logic WiringOpto Isolated Inputs Analog OutputExternal Trip Connection Jumper J19 Selections Jumper J19 Input SelectionSelection Of Operation Mode And Connection Diagrams Speed Select Wire Run/Stop ConnectionsFunction Ramp Select PS2 PS1Parameter 21 Operating Mode = 4 or Parameter 21 Operating Mode = Wire Run/Stop, Electronic Potentiometer ConnectionsAnalog Meter MOL Terminal Connections 77-External Trip SelectRelay Output Installation Check of Electrical Items Pre-Operation ChecksCheck of Motors/Couplings Pre-Operation Check List Temporary Application of PowerInstallation Keypad Key Functions Section OperationOperation Status Indication Operating Condition Keypad Status IndicatorDescription of Keypad Displays Stop Mode Symbol DescriptionRun Mode Program Mode Control Operation AdjustmentSecurity Access/Lockout Level One Parameter Adjustments Start Control Type of Control Parameter 21-Operating Mode ValueCommand Control Terminals Description FWD REV PS1 PS2 Operation Operation Parameter 71-ANALOG Output Select Parameter 75-RELAY Output Select Value Description Level Two Parameter AdjustmentsOperation Operation Parameter 41-ACCEL/DECEL/COAST Select Value Description Operation Parameter 41-Parameter 47-DC Brake Time Braking Action / Function DC Braking DisabledLinear Volts/Hertz Profiles50% Square LawOperation Operation Description / Function Parameter 77-External Trip SelectParameter 81-Factory Settings Value Description Parameter 82-Start Options Value Description Command is given at the Control Terminal Strip Operation Diagnostic Displays Section TroubleshootingFault Codes Fault Code Description Troubleshooting MaintenanceIndication Possible Cause Corrective Action Motor overloadedSpeeds AdjustedOverload Input voltage too high Troubleshooting Illustrations Illustrations HP Nema 230 & 460VAC Illustrations Parameter List Appendix a ParametersParameter List ± Param Parameter Description Adj Factory User Range SettingForm 1099A Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792 Baldor Electric Company MN710 98 C&J2500

ID101F50-E specifications

The Baldor ID101F50-E is an advanced industrial electric motor designed for a variety of heavy-duty applications. Known for its robust construction and high efficiency, this motor is a preferred choice in manufacturing, conveyor systems, and automated machinery where reliability and performance are critical.

One of the primary features of the ID101F50-E is its outstanding efficiency rating. With high efficiency levels, it helps reduce energy consumption, which not only lowers operating costs but also aligns with modern demands for sustainability in industrial practices. The motor's efficiency contributes to a reduced carbon footprint, making it a more environmentally friendly option.

Another significant characteristic of the Baldor ID101F50-E is its high power output. This motor can deliver substantial torque, making it suitable for applications requiring heavy lifting and durable operation. Its design allows for continuous operation at high loads without overheating, which is essential for industries that rely on uninterrupted functionality.

In terms of construction, the ID101F50-E is built with high-quality materials that ensure durability and longevity. The robust housing and premium internal components assist in protecting the motor from harsh environmental conditions, making it well-suited for demanding industrial environments. Its rugged construction means it can withstand vibration, extreme temperatures, and exposure to contaminants.

The motor also incorporates advanced technologies that enhance its performance. For instance, it employs precision engineering techniques in its rotor and stator designs, which minimize losses during operation. This contributes to its overall high performance and reliability. Additionally, the ID101F50-E features advanced cooling mechanisms to maintain optimal operating temperatures, ensuring stability and longevity.

Further enhancing its usability, the Baldor ID101F50-E is designed for easy installation and maintenance. Its standard mounting configurations allow for straightforward integration into existing systems. Maintenance access is simplified, which reduces downtime and helps keep production schedules on track.

In conclusion, the Baldor ID101F50-E is a powerful electric motor that strikes an excellent balance between performance, efficiency, and durability. Its high efficiency, significant power output, robust construction, and advanced technologies make it an ideal choice for various industrial applications, standing as a testament to Baldor's commitment to innovation and quality in electric motor design.