Baldor ID101F50-E manual Operation

Page 46

67-Timed Overload Trip - Sets the amount of overload that will cause a Timed Overload fault (F20) to occur. A Timed Overload fault will occur when the output current reaches 150% of the set value for 1 minute. The Timed Overload Trip is active between 30-100% of the Inverter Rated Current (03-Rated Current) parameter value. The value of the Timed Overload Trip parameter should be calculated by the following formula:

Value of Parameter 67 + Motor FLA X 100 03±Rated Current

The range of adjustment is from 0 to 100%. The factory setting is 0%. The Timed Overload Trip for various output frequencies is shown in the following figure:

Trip Time (Min)

6

5

4

3

2

1

0

0 20 >40Hz

0

50%

100%

150%

70-Analog Output Scale - Allows scaling of the analog meter output at control terminal MET to be more or less than the normal 0-10 VDC level. The factory setting is for 10 VDC output at full inverter output. The adjustable range is 0-255 in digital units.

Operation 3-11

Image 46
Contents Series Inverter Control Installation and Operating Manual MN710Table of Contents Level One Parameter Adjustments Min Output Frequency Appendix a Limited Warranty Section General InformationSafety Notice General Information Specifications NemaElectronic Potentiometer Analog Outputs Fault ConditionsOperator Keypad Relay OutputsCatalog No Input Output RatingsAmps Volts General Information Section Installation Location and MountingTerminal Access Cover Removal Wiring Considerations Terminal and Jumper LocationsInstallation Breaker Fast Time AWG Cu Acting Delay Wire Size and Protection DevicesRated Input Input Fuses Catalog No Main Circuit Wiring AC Power Connections Motor Connections Contactor Typical Connections for M-ContactorLogic Wiring Analog Command InputsOpto Isolated Inputs Analog OutputExternal Trip Connection Jumper J19 Input Selection Jumper J19 SelectionsSelection Of Operation Mode And Connection Diagrams Speed Select Wire Run/Stop ConnectionsFunction PS2 PS1 Ramp SelectParameter 21 Operating Mode = 4 or Wire Run/Stop, Electronic Potentiometer Connections Parameter 21 Operating Mode =Analog Meter MOL Terminal Connections 77-External Trip SelectRelay Output Installation Check of Electrical Items Pre-Operation ChecksCheck of Motors/Couplings Temporary Application of Power Pre-Operation Check ListInstallation Section Operation Keypad Key FunctionsOperation Keypad Status Indicator Status Indication Operating ConditionDescription of Keypad Displays Stop Mode Symbol DescriptionRun Mode Program Mode Control Operation AdjustmentSecurity Access/Lockout Level One Parameter Adjustments Parameter 21-Operating Mode Value Start Control Type of ControlCommand Control Terminals Description FWD REV PS1 PS2 Operation Operation Parameter 71-ANALOG Output Select Level Two Parameter Adjustments Parameter 75-RELAY Output Select Value DescriptionOperation Operation Parameter 41-ACCEL/DECEL/COAST Select Value Description Operation Braking Action / Function DC Braking Disabled Parameter 41-Parameter 47-DC Brake Time50% Square Volts/Hertz ProfilesLinear LawOperation Operation Parameter 77-External Trip Select Description / FunctionParameter 81-Factory Settings Value Description Parameter 82-Start Options Value Description Command is given at the Control Terminal Strip Operation Section Troubleshooting Diagnostic DisplaysFault Codes Fault Code Description Indication Possible Cause Corrective Action MaintenanceTroubleshooting Motor overloadedSpeeds AdjustedOverload Input voltage too high Troubleshooting Illustrations Illustrations HP Nema 230 & 460VAC Illustrations Appendix a Parameters Parameter ListParam Parameter Description Adj Factory User Range Setting Parameter List ±Form 1099A Box Fort Smith, AR 72902±2400 501 646±4711 Fax 501 648±5792 Baldor Electric Company MN710 98 C&J2500

ID101F50-E specifications

The Baldor ID101F50-E is an advanced industrial electric motor designed for a variety of heavy-duty applications. Known for its robust construction and high efficiency, this motor is a preferred choice in manufacturing, conveyor systems, and automated machinery where reliability and performance are critical.

One of the primary features of the ID101F50-E is its outstanding efficiency rating. With high efficiency levels, it helps reduce energy consumption, which not only lowers operating costs but also aligns with modern demands for sustainability in industrial practices. The motor's efficiency contributes to a reduced carbon footprint, making it a more environmentally friendly option.

Another significant characteristic of the Baldor ID101F50-E is its high power output. This motor can deliver substantial torque, making it suitable for applications requiring heavy lifting and durable operation. Its design allows for continuous operation at high loads without overheating, which is essential for industries that rely on uninterrupted functionality.

In terms of construction, the ID101F50-E is built with high-quality materials that ensure durability and longevity. The robust housing and premium internal components assist in protecting the motor from harsh environmental conditions, making it well-suited for demanding industrial environments. Its rugged construction means it can withstand vibration, extreme temperatures, and exposure to contaminants.

The motor also incorporates advanced technologies that enhance its performance. For instance, it employs precision engineering techniques in its rotor and stator designs, which minimize losses during operation. This contributes to its overall high performance and reliability. Additionally, the ID101F50-E features advanced cooling mechanisms to maintain optimal operating temperatures, ensuring stability and longevity.

Further enhancing its usability, the Baldor ID101F50-E is designed for easy installation and maintenance. Its standard mounting configurations allow for straightforward integration into existing systems. Maintenance access is simplified, which reduces downtime and helps keep production schedules on track.

In conclusion, the Baldor ID101F50-E is a powerful electric motor that strikes an excellent balance between performance, efficiency, and durability. Its high efficiency, significant power output, robust construction, and advanced technologies make it an ideal choice for various industrial applications, standing as a testament to Baldor's commitment to innovation and quality in electric motor design.